The Schneider Electric QDA222004 circuit breaker is engineered for effective performance, featuring a line rated current of 200 A and two poles for versatile applications. This device operates within a voltage range of up to 240 V and supports thermal-magnetic trip technology for enhanced reliability in overload conditions.

Call for an immediate quote
2 Year DO Supply Warranty
Available
Ships from Raleigh, NC
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for QDA222004

ManufacturerSchneider Electric
Product TypeCircuit Breaker
Product LinePowerPact
Part NumberQDA222004
UPC785901838425
Weight5.00 lbs (2.27 kg)
Line Rated Current200 A
Number of Poles2
Control TypeOperating Handle
Breaking Capacity CodeD
Breaking Capacity25 kA
Rated Operational Voltage240 V
Minimum Operating Frequency50 Hz
Maximum Operating Frequency60 Hz
Rated Impulse Withstand Voltage8 kV
Trip Unit TechnologyThermal-Magnetic
Magnetic Tripping Current2400 A
Magnetic Hold Current1200 A
Continuous Current Rating80%
Mounting ModeI-Line Bracket

The QDA222004 from Schneider Electric is a robust circuit breaker utilized in multiple electrical settings. This circuit protection device operates at a line rated current of 200 A and features two poles to manage power distribution effectively. The product incorporates an operating handle for easy control and accessibility. With a breaking capacity rating of 25 kA, this circuit breaker can tackle substantial fault conditions, ensuring safe disconnection in the event of power surges.

Operating within a voltage rating of 240 V, this breaker is built to function efficiently across a frequency spectrum of 50 Hz to 60 Hz. It also possesses a rated impulse withstand voltage of 8 kV, which adds a layer of protection against voltage spikes. The thermal-magnetic trip technology installed in this unit safeguards against both overload and short-circuits, providing reliable tripping responses when necessary.

The magnetic trip feature allows for a tripping current of 2400 A, while holding current is set at 1200 A, validating its capability to maintain operational stability under typical load conditions. For installations, the QDA222004 can be conveniently mounted via an I-Line bracket, optimizing space utilization in control panels or distribution boards. Its continuous current rating of 80% indicates dependable performance when handling consistent loads.