The Schneider Electric QDA222004 circuit breaker is engineered for effective performance, featuring a line rated current of 200 A and two poles for versatile applications. This device operates within a voltage range of up to 240 V and supports thermal-magnetic trip technology for enhanced reliability in overload conditions.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Schneider Electric |
|---|---|
| Product Type | Circuit Breaker |
| Product Line | PowerPact |
| Part Number | QDA222004 |
| UPC | 785901838425 |
| Weight | 5.00 lbs (2.27 kg) |
| Line Rated Current | 200 A |
| Number of Poles | 2 |
| Control Type | Operating Handle |
| Breaking Capacity Code | D |
| Breaking Capacity | 25 kA |
| Rated Operational Voltage | 240 V |
| Minimum Operating Frequency | 50 Hz |
| Maximum Operating Frequency | 60 Hz |
| Rated Impulse Withstand Voltage | 8 kV |
| Trip Unit Technology | Thermal-Magnetic |
| Magnetic Tripping Current | 2400 A |
| Magnetic Hold Current | 1200 A |
| Continuous Current Rating | 80% |
| Mounting Mode | I-Line Bracket |
The QDA222004 from Schneider Electric is a robust circuit breaker utilized in multiple electrical settings. This circuit protection device operates at a line rated current of 200 A and features two poles to manage power distribution effectively. The product incorporates an operating handle for easy control and accessibility. With a breaking capacity rating of 25 kA, this circuit breaker can tackle substantial fault conditions, ensuring safe disconnection in the event of power surges.
Operating within a voltage rating of 240 V, this breaker is built to function efficiently across a frequency spectrum of 50 Hz to 60 Hz. It also possesses a rated impulse withstand voltage of 8 kV, which adds a layer of protection against voltage spikes. The thermal-magnetic trip technology installed in this unit safeguards against both overload and short-circuits, providing reliable tripping responses when necessary.
The magnetic trip feature allows for a tripping current of 2400 A, while holding current is set at 1200 A, validating its capability to maintain operational stability under typical load conditions. For installations, the QDA222004 can be conveniently mounted via an I-Line bracket, optimizing space utilization in control panels or distribution boards. Its continuous current rating of 80% indicates dependable performance when handling consistent loads.