Product image is representative; revision or series may vary. Contact us to request a specific version.
The Schneider Electric QDL32090 is a robust circuit breaker engineered for reliable operation. Designed for three-pole configurations, it has a line-rated current of 90 A and a breaking capacity of 25 kA, making it suitable for various applications.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Schneider Electric |
|---|---|
| Product Type | Circuit Breaker |
| Product Line | PowerPact |
| Part Number | QDL32090 |
| UPC | 785901522874 |
| Weight | 5.00 lbs (2.27 kg) |
| Line Rated Current | 90 A |
| Number of Poles | 3 |
| Control Type | Operating Handle |
| Breaking Capacity Code | D |
| Breaking Capacity | 25 kA |
| Rated Operational Voltage | 240 V AC |
| Network Frequency | 50/60 Hz |
| Rated Impulse Withstand Voltage | 8 kV |
| Trip Unit Technology | Thermal Magnetic |
| Magnetic Tripping Current | 1800 A |
| Magnetic Hold Current | 1000 A |
| Continuous Current Rating | 80% |
| Mounting Mode | Unit Mount Lug |
| Tightening Torque | 247.8 lbf.in |
The QDL32090 from Schneider Electric's PowerPact series is a reliable circuit breaker that effectively manages electrical circuits. With a line-rated current of 90 amps, this circuit breaker is constructed with three poles to ensure efficient distribution across multiple circuits. This unit handles a substantial breaking capacity of 25 kA, offering peace of mind in high-demand situations. The device operates at a voltage level of 240 V AC and is suited for both 50 Hz and 60 Hz networks. Its rated impulse withstand voltage stands at 8 kV, enhancing its ability to resist voltage surges. The trip unit employs thermal magnetic technology, incorporating features for thermal protection alongside a magnetic tripping capability that activates at a current of 1800 A. In normal operation, the breaker maintains a magnetic hold current of 1000 A, which supports continuous use at 80% of its rated capacity. For installation, the unit mount lug mode simplifies the setup process, ensuring secure attachment. Additionally, this circuit breaker requires a tightening torque of 247.8 lbf.in for secure connections, contributing to its overall efficacy in circuit protection.