Product image is representative; revision or series may vary. Contact us to request a specific version.
The QDP22125TM from Schneider Electric is a robust circuit breaker designed to handle a line-rated current of 125 A across two poles. This device offers a breaking capacity of 25 kA, ensuring reliability under fault conditions, coupled with a magnetic trip current rating of 2400 A.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Schneider Electric |
|---|---|
| Product Type | Circuit Breaker |
| Product Line | PowerPact |
| Part Number | QDP22125TM |
| UPC | 785901672548 |
| Weight | 3.00 lbs (1.36 kg) |
| Line Rated Current | 125 A |
| Number of Poles | 2 |
| Control Type | Operating Handle |
| Breaking Capacity Code | D |
| Breaking Capacity | 25 kA |
| Rated Operational Voltage | 240 V AC |
| Network Frequency | 50/60 Hz |
| Rated Impulse Withstand Voltage | 8 kV |
| Trip Unit Technology | Thermal Magnetic |
| Magnetic Tripping Current | 2400 A |
| Magnetic Hold Current | 1200 A |
| Continuous Current Rating | 80% |
| Mounting Mode | Unit Mount Lug |
| Tightening Torque | 247.8 lbf.in |
The Schneider Electric QDP22125TM circuit breaker is engineered for efficient protection in electrical systems. Designed for a line-rated current of 125 A, this two-pole circuit breaker is ideal for various applications requiring high reliability in electrical distribution. The device exhibits a substantial breaking capacity of 25 kA, ensuring effective interruption of fault currents.
Built to operate at a nominal voltage of 240 V AC, the QDP22125TM is set to function seamlessly with a network frequency of 50 or 60 Hz. With a rated impulse withstand voltage of 8 kV, it provides the necessary protection against transient overvoltages that could potentially damage electrical circuits.
The circuit breaker utilizes a thermal magnetic trip unit technology, where the magnetic trip current is rated at 2400 A, while the magnetic hold current stands at 1200 A. The continuous current rating operates efficiently at 80%, enhancing the overall performance. For installation, the unit employs a mounting mode designed for connection via lug terminals and requires a tightening torque of 247.8 lbf.in. The control type is via an operating handle, allowing straightforward manual operation of the breaker. Overall, the QDP22125TM circuit breaker is a critical component in safeguarding electrical systems while providing reliable power management.