Product image is representative; revision or series may vary. Contact us to request a specific version.
The Schneider Electric QGL32070 circuit breaker from the PowerPact series is engineered for dependable performance. It functions at a rated voltage of 240 V AC and includes a thermal-magnetic trip unit technology.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Schneider Electric |
|---|---|
| Product Type | Circuit Breaker |
| Product Line | PowerPact |
| Part Number | QGL32070 |
| UPC | 785901603474 |
| Weight | 5.00 lbs (2.27 kg) |
| Magnetic Trip Current | 1800 A |
| Continuous Current Rating | 80 % |
| Mounting Mode | Unit mount (lugs both ends) |
| Tightening Torque | 28 N·m |
| Impulse Withstand Voltage | 8 kV |
| Local Signaling | 1 green trip indicator |
| Line Rated Current | 70 A |
| Rated Voltage | 240 V AC (50/60 Hz) |
| Number of Poles | 3 |
| Interrupting Capacity | 65 kA @ 240 V AC |
| Breaking Capacity Code | G |
| Trip Unit Technology | Thermal-magnetic |
| Magnetic Hold Current | 1000 A |
The QGL32070 model signifies a circuit breaker component in the Schneider Electric PowerPact series, designed to provide reliable protection and control. This unit mounts easily with lugs located at both ends, making installation straightforward. The circuit breaker has dimensions measuring 6.47 inches in height, 4.5 inches in width, and 3.93 inches in depth.
It features a continuous current capacity rated at 70 A, combined with an 80% continuous current rating. The trip unit uses thermal-magnetic technology, enhancing its ability to respond to overload and short circuit conditions effectively. A significant characteristic is its magnetic trip current, which registers at 1800 A, ensuring prompt operation during fault conditions.
The circuit breaker is designed to manage an interrupting capacity of 65 kA at 240 V AC, providing safety in protecting circuits from overload. The impulse withstand voltage is rated at 8 kV, signifying its robustness against voltage spikes.
Local signaling includes a green trip indicator, allowing for quick visual confirmation of the breaker status. For installation, it requires a tightening torque of 28 N·m, providing the necessary securing force. In addition, the magnetic hold current for this device is rated at 1000 A, emphasizing its ability to maintain current flow under steady-state conditions while offering enhanced protection against fluctuations.