Free UPS Ground on All Orders!
+1 (919) 205-4392
Schneider Electric Square D NQ442L2C

Product image is representative; revision or series may vary. Contact us to request a specific version.

NQ442L2C

|

The Schneider Electric NQ442L2C is an interior panelboard designed for efficient electrical distribution. Engineered with 42 spaces, it operates at a line current of 225 Amps and supports both 240V AC and 48V DC voltage ratings.

In Stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for NQ442L2C

ManufacturerSchneider Electric
Product LineSquare D
Part NumberNQ442L2C
UPC785901507871
Weight21.00 lbs (9.53 kg)
TypeInteriors Panelboard
Panelboard TypeMain Lugs
Busbar MaterialCopper
Number of Spaces42 Spaces
Line Current225 Amps
AC Voltage Rating240V AC
DC Voltage Rating48V DC
Operating Temperature0 to 40 degrees Celsius
Storage Temperature0 to 50 degrees Celsius
Maximum Operating Humidity80% RH (non-condensing)
Maximum Storage Humidity80% RH (non-condensing)
Maximum Operating Altitude1000 meters above sea level without derating
Maximum Storage Altitude1000 meters above sea level
EnvironmentClean indoor environment with no corrosive chemicals

The NQ442L2C by Schneider Electric is an interior panelboard and is part of the reputable Square D series. This panelboard features a main lug configuration and incorporates copper as the busbar material for reliable conductivity. It provides 42 spaces, accommodating various electrical connections and setups.

A critical specification of this panelboard is its capability to handle a line current of up to 225 Amps. The electrical ratings include an AC voltage of 240V and a DC rating of 48V, offering versatility for different electrical applications. The design is suitable for operation within a temperature range of 0 °C to 40°C, ensuring reliable performance in typical indoor environments.

Storage conditions should maintain temperatures between 0 and 50 degrees Celsius, with the panelboard capable of functioning effectively up to an altitude of 1000 meters above sea level without any derating of its capabilities. The same maximum altitude applies for safe storage.

In terms of humidity, the NQ442L2C operates in conditions with a maximum relative humidity of 80% (non-condensing), ensuring that moisture levels do not compromise its performance. The environment for installation should stay free from corrosive chemicals, maintaining a clean indoor atmosphere to protect the integrity of the panelboard.