| Manufacturer | Schneider Electric |
|---|---|
| Product Type | Thermal Overload Relay |
| Product Line | TeSys |
| Part Number | LR2-D1307 |
| Weight | 0.38 lbs (0.17 kg) |
| Current Adjustment Range | 1.6 to 2.5 A |
| Trip Class | Class 10A |
| Relay Application | Motor Protection |
| Rated Operational Voltage (Ue) | 690 Volts AC, 50/60 Hz |
| Network Frequency | 50/60 Hz |
| Tripping Threshold | 1.14 ± 0.06 × In A |
| Phase-Failure Sensitivity | Tripping Current 30% of Ir on One Phase, Remaining Phases at Ir |
| Surge Withstand | 6 kV |
| Dielectric Strength | 6 kV at 50 Hz |
| Control Circuit Protection Fuse | BS Type: 5 Amps, gG Type: 5 Amps |
| Control Circuit Protection Using GB2 Circuit Breaker | 5 A |
| Control Terminal Conductor Size | 1 to 2.5 mm² |
| Control Terminal Tightening Torque | 1.7 N·m |
The Schneider Electric LR2-D1307 is categorized as a thermal overload relay, explicitly aimed at safeguarding motors in electrical applications. This relay supports a current adjustment range from 1.6 to 2.5 A, making it suitable for diverse motor configurations. Weighing just 0.40 lbs, this component is lightweight yet robust, facilitating easy installation and maintenance.
Rated for a maximum operational voltage of 690 Volts AC, the LR2-D1307 is compliant with both 50 Hz and 60 Hz frequencies. The trip class rating of 10A indicates it is specifically designed to trigger when an overload condition is detected, thus ensuring optimal motor protection. The tripping threshold is established at 1.14 ± 0.06 × In A, which helps prevent any damage during abnormal operational conditions.
Additionally, this relay exhibits phase-failure sensitivity; in the event of current draw reduction on one phase, it will trip at 30% of the rated current. It can also withstand a surge of up to 6 kV, accompanied by a dielectric strength of 6 kV at 50 Hz.
For control circuit protection, the device requires a fuse rated at 5 Amps, either of BS type or gG type, for added safety. If utilizing a GB2 circuit breaker for control circuit protection, a setting of 5 A is recommended. The control terminal supports conductor sizes ranging from 1 to 2.5 mm² and necessitates a tightening torque of 1.7 N·m to ensure a secure connection. This overload relay effectively combines reliability, safety, and ease of use for motor protection applications.