Product image is representative; revision or series may vary. Contact us to request a specific version.
The model 3VA4180-5ED34-0AA0 from Siemens is a molded case circuit breaker (MCCB) specifically designed for fixed mounting applications. It supports an operating voltage up to 600 V and a rated current of 80 A, ensuring reliable circuit protection.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Siemens |
|---|---|
| Product Type | Molded Case Circuit Breaker (MCCB) |
| Product Line | SENTRON |
| Part Number | 3VA4180-5ED34-0AA0 |
| UPC | 804766944123 |
| Mounting Type | Fixed Mount (FTFM) |
| Frame Size | UL Frame 125 |
| Frequency Rating | 50/60 Hz |
| Power Loss [W] / Maximum | 16.5 W |
| Power Loss [W] / for Rated Value of the Current / at AC / in Hot Operating State / Per Pole | 5.5 W |
| Overload Protection (Ir) | 80 A (Fixed) |
| Trip Unit Type | Thermal-Magnetic (TM210) |
| Number of Poles | 3 Poles |
| Operating Voltage / at AC / Rated Value | 600 V |
| Rated Current (In) | 80 A |
The Siemens 3VA4180-5ED34-0AA0 is an efficient molded case circuit breaker (MCCB) within the SENTRON series. It is engineered for fixed mounting (FTFM) and is housed in a UL Frame 125 size. Capable of managing a maximum operating voltage of 600 V, this unit ensures that heavy electrical loads can be handled without compromising safety.
Designed for use in both 50 and 60 Hz frequency environments, the breaker operates with a rated current of up to 80 A. In terms of power consumption, it has a maximum power loss of 16.5 W. Each pole incurs a power loss of 5.5 W during hot operation, allowing for efficient management of energy distribution.
This circuit breaker is equipped with a thermal-magnetic trip unit, designated as TM210, which provides functional overload protection at a fixed setting of 80 A. It comprises three poles to handle three-phase circuits effectively. Additionally, it features impressive interrupting capacities: an 18 kA rating at 600 Y/347 V, 35 kA at both 480 V and 480 Y/277 V, and a robust 85 kA at 240 V, ensuring reliability in event of fault conditions. Overall, the Siemens 3VA4180-5ED34-0AA0 MCCB combines advanced protective features with robust performance for dependable electrical system management.