Siemens' HLMXD63B800 is a molded case circuit breaker designed for efficient control and safeguarding of electrical circuits. With a trip current rating of 800 Amperes, it operates at nominal voltages of up to 500 Volts DC and 600 Volts AC, suitable for 3-phase systems.

Call for an immediate quote
2 Year DO Supply Warranty
Available
Ships from Raleigh, NC
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for HLMXD63B800

ManufacturerSiemens
Product TypeMolded Case Circuit Breaker
Product LineSENTRON
Part NumberHLMXD63B800
UPC783643304048
System Frequency50 to 60 Hertz
Trip FunctionsLong-Time and Instantaneous (LI)
Interrupt Rating65 kiloamperes at 480 Volts AC
Rated Trip Current800 Amperes
Nominal Voltage500 Volts DC / 600 Volts AC
Trip Unit TypeThermal magnetic trip unit
Trip StyleNon-interchangeable
Poles Design3 poles
Phase Type3-phase
Mounting StyleBolt-on mount
Trip Range3,200 to 8,000 Amperes
Type of FrameLMD frame

The HLMXD63B800, part of Siemens' SENTRON series, is engineered as a molded case circuit breaker. Its robust construction makes it well-suited for essential electrical management tasks in demanding environments. Designed to function effectively within a frequency range of 50 to 60 Hertz, this unit supports a rated trip current of 800 Amperes. This capability ensures the breaker can handle significant loads, making it ideal for varied industrial installations.

In terms of interruption capacity, the breaker can manage fault currents of up to 65 kiloamperes at 480 Volts AC. This high interrupt rating affirms its reliability during unexpected electrical surges. The circuit breaker operates at nominal voltages of 500 Volts for DC operations and up to 600 Volts for AC, contributing to its versatility in application.

It utilizes a thermal magnetic trip unit designed for effective protection against overload and short-circuit conditions. The trip style is non-interchangeable, which simplifies installation processes. The internal design consists of three poles, allowing it to be integrated within a 3-phase system effectively. The unit's frame type is the LMD frame, and it features a trip range adjustable between 3,200 and 8,000 Amperes. For installation, it follows a bolt-on mount procedure, ensuring a secure and stable configuration in electrical panels.