4AM4342-8DD40-0FB0

|

The Siemens 4AM4342-8DD40-0FB0 functions as an isolation transformer specifically designed for control circuits. This single-phase device offers primary nominal power of 0.315 kVA and secondary nominal power of 1.12 kVA, accommodating a variety of voltages with adjustable taps.

Call for an immediate quote
2 Year DO Supply Warranty
Available
Ships from Raleigh, NC
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for 4AM4342-8DD40-0FB0

ManufacturerSiemens
Product LineSIDAC
Part Number4AM4342-8DD40-0FB0
UPC754554776897
Weight11.00 lbs (4.99 kg)
TypeIsolation transformer for control circuits
PhasesSingle-phase (1-phase)
Primary Nominal Power (PN)0.315 kVA (kilovolt-amps)
Secondary Nominal Power (PN(S6))1.12 kVA
Primary Voltage Range (UPRI)550V, 525V, 500V, 480V, 460V, 440V, 415V, 400V, 380V, 230V, 208V (adjustable taps)
Secondary Voltage (USEC)2 x 115V AC
Secondary Current (ISEC)1.37A to 2.74A (depending on the load)
Frequency50 Hz to 60 Hz (compatible with both)
Vector Group / Shield WindingII0 / 0 (specific winding configuration and neutral connection)
Insulation Class (TA/ISOKL)40 (temperature rise) / B (insulation class)
Protection Class (IP Rating)IP00 (no protection against dust or water ingress)
Type of TerminalsScrew or tab connection terminals
Installation MethodMounting via screws (for securing the transformer to surfaces)
Standards ComplianceUL/CSA- North American markets and EN 61558-2-1, EN 61558-2-2, EN 61558-2-4 (European transformer standards)
FunctionProvides electrical isolation between the control system and the power supply

The Siemens model 4AM4342-8DD40-0FB0 isolation transformer is tailored for control circuit applications. This unit operates as a single-phase transformer, offering a primary nominal power of 0.315 kVA and a secondary nominal power rated at 1.12 kVA. Users can adjust the primary voltage across a range of options, including 550V, 525V, 500V, and several others down to 208V, enabling flexibility depending on the specific requirements of the setup.

The secondary outputs deliver 2 x 115V AC, with secondary current adjustable from 1.37 to 2.74A depending on attached load. This transformer accommodates frequencies from 50 Hz to 60 Hz, ensuring compatibility in diverse operational environments. The vector group configuration is designated as II0/0, highlighting its specific winding arrangement and neutral connection for optimized functioning.

Additionally, the transformer adheres to an insulation class rated B, with a temperature rise tolerance of 40. Its IP00 rating indicates that there is no protection against the ingress of dust or water, making careful placement essential. Here, standard screw or tab terminals allow for straightforward connection, and the installation method involves mounting via screws, securing the transformer to the required surface effectively.

This model complies with several significant standards in the North American market (UL/CSA) as well as EN 61558-2-1, EN 61558-2-2, and EN 61558-2-4 for European transformer standards. Its primary function is to provide electrical isolation between the control system and the power supply, ensuring safe and efficient operation.