Product image is representative; revision or series may vary. Contact us to request a specific version.
The Siemens 6SL3000-0BE21-6AA0 is a line filter specifically designed for the Active Line Module within the SINAMICS S120 series. With a power rating of 16 kW, this filter operates effectively with input voltages ranging between 380 and 480 V AC in a three-phase configuration.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Siemens |
|---|---|
| Product Type | Line filter for Active Line Module |
| Product Line | SINAMICS S120 |
| Part Number | 6SL3000-0BE21-6AA0 |
| UPC | 662643066425 |
| Weight | 20.00 lbs (9.07 kg) |
| Rated Power | 16 kW |
| Input Voltage | 380-480 V AC |
| Phases | 3-phase |
| Frequency | 50/60 Hz |
| EMC Standard | EN 61800-3 |
| EMC Category | C2, C3, C4 (varies by setup) |
| Motor Cable | Shielded, low capacitance |
| Max Cable Length | Up to 100 m (varies by module) |
| Line Impedance | ≥ 4% or low harmonic filter for compliance |
| Pulse Frequency | ≤ 4 kHz (Blocksize), ≤ 2 kHz (Chassis) |
| Additional Filters | May be needed for stricter EMC compliance |
The 6SL3000-0BE21-6AA0 line filter from Siemens is integral to the Active Line Module of the SINAMICS S120 series. It is rated for a power output of 16 kW and is designed to function with a three-phase input voltage within the range of 380 to 480 V AC. This model handles frequencies operating at either 50 or 60 Hz, making it versatile for various applications.
This line filter conforms to the EMC requirements as defined in the EN 61800-3 standard and supports multiple EMC categories based on the specific setup, including C2, C3, and C4 classifications. It ensures compatibility with shielded, low-capacitance motor cables, which is critical for maintaining signal integrity. The maximum permissible cable length reaches up to 100 meters, but it is subject to variability depending on the specific module in use.
With a baseline line impedance of at least 4%, this filter is engineered to ensure compliance with harmonic specifications. Additionally, it incorporates features to handle pulse frequencies of up to 4 kHz for blocksize configurations and 2 kHz for chassis setups. In scenarios where more stringent EMC compliance is necessary, additional filtering solutions may be required to achieve desired performance levels.