Free UPS Ground on All Orders!
+1 (919) 205-4392
Siemens SINAMICS S120 6SL3000-0DE31-2AA1

Product image is representative; revision or series may vary. Contact us to request a specific version.

6SL3000-0DE31-2AA1

|

The Siemens 6SL3000-0DE31-2AA1 is an HFD line reactor designed for compatibility with the 120 kW E/R module. It operates at a voltage range of 3AC 380–480 V and handles a current rating of 240 A, crucial for effective motor control applications.

In Stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for 6SL3000-0DE31-2AA1

ManufacturerSiemens
Product LineSINAMICS S120
Part Number6SL3000-0DE31-2AA1
UPC662643510171
Weight150.00 lbs (68.04 kg)
Product NameHFD Line Reactor
Compatible Modules120 kW E/R Module
Voltage Rating3AC 380–480 V
Current Rating240 A
Inductance0.15 mH
Protection ClassIP00
Operating Temperature Range0–40 °C
Storage Temperature Range-20–70 °C
Humidity95% or less, non-condensing
EnvironmentNo corrosive gases
Altitude2000 m / 6562 ft

Siemens' 6SL3000-0DE31-2AA1 serves as a highly functional HFD line reactor within the SINAMICS S120 series. This unit provides critical support for the 120 kW E/R module, allowing for a seamless integration in motor control systems.

Designed to operate within a voltage range from 3AC 380 to 480 volts, it is capable of handling a considerable current of 240 amps. Inductance is specified at 0.15 mH, which contributes to stable performance and reduced harmonics.

Protected by an IP00 rating, it has robust construction suitable for various applications. Its dimensions measure 450 mm in height, 540 mm in width, and 380 mm in depth, translating to 17.72 inches by 21.26 inches by 14.96 inches. With a weight of 68 kg (or 149.91 lbs), this reactor is a solid component for installations requiring reliable operation.

The HFD line reactor is optimized for environments with operational temperatures ranging from 0 to 40 °C. It can be stored safely within a temperature scope of -20 to 70 °C. Humidity levels should be maintained at or below 95% without condensation. Furthermore, it is crucial to use this reactor in non-corrosive environments to ensure longevity. Support for installations up to 2000 meters (6562 feet) in altitude is also a key feature, enhancing its versatility across diverse industrial applications.