Siemens SIRIUS 3RT1056-6AU36

Product image is representative; revision or series may vary. Contact us to request a specific version.

3RT1056-6AU36

|

Siemens' 3RT1056-6AU36 is a power contactor showcasing robust electrical characteristics. Designed with three poles, it accommodates high insulation voltages and assures reliable performance in diverse applications.

Call for an immediate quote
2 Year DO Supply Warranty
Available
Ships from Raleigh, NC
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for 3RT1056-6AU36

ManufacturerSiemens
Product LineSIRIUS
Part Number3RT1056-6AU36
UPC754554771779
Weight7.00 lbs (3.18 kg)
ProductPower Contactor
Auxiliary SwitchYes
Power Loss (Hot Operating State)39 W
Power Loss (Hot Operating State Per Pole)13 W
Insulation Voltage (Main Circuit)1000 V
Insulation Voltage (Auxiliary Switch)500 V
Surge Voltage Resistance8 kV
Shock Resistance (Rectangular Impulse)8.5g / 5 ms, 4.2g / 10 ms
Installation Altitude (Maximum)2000 m above sea level
Number of Poles for Main Current Circuit3
Closing Power of Magnet Coil at DC360 W
Holding Power of Magnet Coil at DC5.2 W
Closing Delay20 to 96 ms
Arcing Time10 to 15 ms

The Siemens 3RT1056-6AU36 power contactor is engineered for reliable control and switching of electrical circuits. It supports a main current circuit comprising three poles, allowing for efficient operation. This device has an auxiliary switch for added functionality. With the insulation voltage rated at 1000 V for the main circuit and 500 V for the auxiliary switch, it guarantees safe performance in various electrical contexts.

Its construction features a surge voltage resistance of up to 8 kV, which is crucial for preventing damage due to voltage spikes. This power contactor is also designed to withstand shock, rated to handle rectangular impulse shocks of 8.5g for 5 milliseconds and 4.2g for 10 milliseconds.

In terms of electrical characteristics, the power loss during hot operation peaks at 39 W, corresponding to 13 W per pole, which is indicative of the contactor's efficiency. Additionally, the unit requires a closing power of 360 W for its DC magnet coil while maintaining a holding power of 5.2 W. The closing delay ranges from 20 to 96 milliseconds, and the arcing time lasts between 10 and 15 milliseconds, which are important factors for the timely and effective operation of control systems. Weighing in at 3.44 kg, the 3RT1056-6AU36 is also suitable for installations at altitudes of up to 2000 meters above sea level, making it versatile for various application environments.