The Yaskawa GPD-315-Quick-References provides essential technical data for users of Yaskawa's GPD series drives. With support for input power configurations of 3-phase 200–230 VAC or 400–460 VAC, this unit allows for flexible integration into various systems.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Yaskawa |
|---|---|
| Product Type | Quick References |
| Product Line | GPD |
| Part Number | GPD-315-Quick-References |
| Input Power | 3-phase 200–230 VAC or 400–460 VAC |
| Control Mode | V/f or Open-loop Vector (n002) |
| Run/Stop Source | Param n001 (2‑/3-wire or Init) |
| Frequency Reference | Param n004 (Operator, Voltage, Serial, etc.) |
| Modbus Baud Rate | Param n154: 2400–19200 bps |
| Modbus Parity | Param n155: None/Even/Odd |
| Node Address | Param n153: 0–31 |
| Slip Compensation | Param n018 (auto/manual) |
| Display Unit | Potentiometer / RPM options (n035) |
| Dynamic Braking | Optional accessory for regenerative loads |
| Ambient Temp Range | –10 to 50 °C |
| Fault History | Last 4 faults via DSPL → U‑09 |
| Mounting Orientation | Vertical with ≥30 mm side clearance |
The Yaskawa GPD-315-Quick-References is a reference tool that features several important specifications for efficient operation of Yaskawa GPD drives. This product is designed to accept input power either from a 3-phase voltage supply of 200–230 VAC or 400–460 VAC. Users can choose between control methods, either V/f or Open-loop Vector (n002), tailored to their specific requirements.
The run/stop command can be configured through Parameter n001, allowing flexibility with either 2‑/3-wire or initialization setups. Parameters for frequency referencing (n004) support various inputs including operator, voltage, and serial commands, facilitating diverse control options. Modbus communication is supported with adjustable baud rates (n154) ranging from 2400 to 19200 bps. Parity settings (n155) offer options including none, even, or odd, while node addresses can be assigned using Parameter n153, with options from 0 to 31.
For improved control, slip compensation is adjustable via Parameter n018, allowing either automatic or manual adjustments. The display unit can utilize a potentiometer or indicate RPM options as per n035. For applications involving regenerative loads, dynamic braking is available as an optional accessory.
This device operates efficiently within ambient temperatures from –10 °C to 50 °C, making it suitable for a variety of environments. Users can also access fault history for the last four faults through the display screen via U-09, offering insights into operational issues. Mounting is recommended in a vertical orientation with at least a 30 mm side clearance to ensure optimal performance.