Free UPS Ground on All Orders!
+1 (919) 205-4392
Yaskawa GPD GPD-333-A-B1747-SDN-Configuration

Product image is representative; revision or series may vary. Contact us to request a specific version.

GPD-333-A-B1747-SDN-Configuration

|

The GPD-333-A-B1747-SDN-Configuration is a scanner module from Yaskawa's GPD series designed for DeviceNet environments. Acting as a master within the network, it connects seamlessly to SLC-500 series controllers through RSNetWorx.

Call for an immediate quote
2 Year DO Supply Warranty
Available
Ships from Raleigh, NC
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for GPD-333-A-B1747-SDN-Configuration

ManufacturerYaskawa
Product TypeScanner Module
Product LineGPD
Part NumberGPD-333-A-B1747-SDN-Configuration
NetworkDeviceNet
RoleIn DeviceNet network: Scanner (Master)
Connected ControllerSLC‑500 series (via RSNetWorx)
Slave DeviceGPD‑333 Drive
Communication ModePolled I/O only
Poll TimingPoll cycle > PCA exec time & PPA exec time
Scan list SetupEnable device, set Rx/Tx byte sizes matching PCA/PPA
I/O MappingConfigured via RSNetWorx Scan list editor
Node AddressSwitch-configured on 1747‑SDN
Poll Rate ModeEvery Scan or Background Scan
Tools RequiredRSNetWorx for DeviceNet & RSLogix SLC

Yaskawa’s GPD-333-A-B1747-SDN-Configuration serves as a scanner module specifically tailored for DeviceNet networks. This device operates in a master role within such a network, enabling effective communication with connected components, including the SLC-500 series controllers via RSNetWorx. The GPD-333 Drive is designated as the slave device linked to this scanner.

In terms of communication, this module exclusively uses the polled I/O communication mode, where the timing of the poll cycle is required to exceed the execution times of both PCA and PPA. This ensures efficient data exchange between devices. The setup of the scan list includes enabling devices and ensuring that receive (Rx) and transmit (Tx) byte sizes align with both PCA and PPA requirements.

I/O mapping is managed through the RSNetWorx Scan list editor, which simplifies the allocation and monitoring of inputs and outputs. Node addresses are configured using a switch on the 1747-SDN, allowing for straightforward installation and adjustments.

Poll rate modes are flexible, with options for either every scan or background scanning, enhancing operational control. To utilize the GPD-333-A-B1747-SDN-Configuration effectively, tools such as RSNetWorx for DeviceNet and RSLogix SLC are necessary, ensuring comprehensive setup and management of networked devices.