Yaskawa GPD GPD-333-Configuration-with-Net-Manager

Product image is representative; revision or series may vary. Contact us to request a specific version.

GPD-333-Configuration-with-Net-Manager

|

The Yaskawa GPD-333-Configuration-with-Net-Manager is designed for use as an AC drive configuration within the GPD series. It operates on the DeviceNet network type, functioning as a slave device. Configuration allows for setting node addresses through DIP switches, making setup straightforward.

Call for an immediate quote
2 Year DO Supply Warranty
Available
Ships from Raleigh, NC
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for GPD-333-Configuration-with-Net-Manager

ManufacturerYaskawa
Product TypeAC Drive Configuration
Product LineGPD
Part NumberGPD-333-Configuration-with-Net-Manager
Network TypeDeviceNet
Node AddressSet via DIP switches on drive
Drive RoleSlave (GPD-333)
Network MasterScanner device (e.g., 1747-SDN / 1771-SDN)
Communication ModePolled I/O
PCA Assembly21 (Extended Speed Control)
PPA Assembly71 (Extended Status)
I/O Byte SizeSet to PCA/PPA byte count
Minimum Poll TimeMust exceed PCA & PPA exec times
Scan ModeEvery Scan or Background Scan
Interscan DelayConfigurable in Net Manager
Scan list SettingsActive & Polled flags enabled
Enter CommandSaves config to EEPROM
Tools RequiredRSNetWorx + EDS file support

The Yaskawa part number GPD-333-Configuration-with-Net-Manager serves as an AC drive configuration, tailored for applications integrating within the DeviceNet network architecture. This configuration is designated to operate as a slave, permitting it to connect to a network master, like the 1747-SDN or 1771-SDN scanner devices. The node address can be adjusted conveniently using DIP switches located on the drive itself, simplifying initial setup.

The communication operates in a polled I/O mode, ensuring efficient data exchange between network components. The PCA assembly configuration is set at 21, offering enhanced speed control capabilities. For monitoring conditions and operational status, the PPA assembly is configured at 71. The I/O byte size is defined based on the PCA and PPA byte count.

Operational timing also plays a crucial role; the minimum poll time must exceed the execution times of both PCA and PPA to ensure proper functionality. Users can select between scan modes—either 'Every Scan' or 'Background Scan'—providing flexibility based on operational requirements. Additionally, the Net Manager allows the configurability of interscan delays optimizing network performance during scanning processes.

To facilitate network management, the scan list settings can enable active and polled flags appropriately. Upon executing the enter command, the configuration is saved directly into the EEPROM, ensuring settings are retained. The configuration requires tools such as RSNetWorx along with EDS file support for complete functionality and integration into control systems.