Technical specifications for GPD-505-Capacity-Parameters

ManufacturerYaskawa
Product TypeAC Drive Parameters
Product LineGPD
Part NumberGPD-505-Capacity-Parameters
Model Range0.75–500 HP
Input Voltage200–240 VAC & 400–480 VAC
Output Current0.75–675 A (model-dependent)
PWM Carrier Frequency2.5–15 kHz depending on size
n032 (Motor FLA)User set to 10–120% of drive rating
n115 (Control PCB Code)Sets factory parameters per rating
n010 (V/f Pattern)Standard V/f curve selection
n012–n018 (Custom V/f)Adjustable volts/hertz curve
n050 (Acceleration Time)Default varies by HP
n053–n055 (Decel, DC Brake timing)Factory defaults per rating
n068 (Overcurrent limit %)Typically 100% n069 (Overload capacity W)
Drive rating × torque n071–n072 (Stall prevention)30–200% default
n096 (Auto-restart count)up to 10x
n115–n116 (Parameter profiles)Auto-set via n115

Within the Yaskawa GPD series, the GPD-505-Capacity-Parameters is engineered to fine-tune AC drive functionalities. It accommodates horsepower ratings from 0.75 to 500 HP, offering versatility for numerous applications. Input voltage requirements span both 200–240 VAC and 400–480 VAC, allowing for flexible deployment in diverse environments. Depending on the specific model, output current capacity ranges from 0.75 to 675 A, providing substantial power handling capabilities.

The drive supports a PWM carrier frequency adjustable from 2.5 kHz to 15 kHz, which varies according to the size of the drive. Specific configurations, such as motor full-load amps (FLA), can be customized between 10% and 120% of the rated capacity. The control PCB code parameter (n115) allows for the establishment of factory defaults tailored to each rating. For standard operations, the V/f pattern is pre-defined, while parameters n012 to n018 enable users to customize volts/hertz curves for their specific needs.

A range of settings, such as acceleration time (n050), is set based on horsepower, and parameter settings for deceleration and DC braking (n053-n055) follow factory defaults suited to the rating. The overcurrent limit is typically set to a standard 100%, with overload capacity reliant on specific drive torque ratings. Additional stall prevention settings can be configured to default between 30% and 200%, ensuring efficient operation during any load variations.

The drive also features an auto-restart count (n096) that allows attempts up to 10 times, providing resilience against unexpected interruptions. Lastly, parameters profiles can be automatically configured via n115, optimizing the setup process. This array of features makes the GPD-505-Capacity-Parameters an essential tool for effective AC drive management in various applications.