| Manufacturer | Yaskawa |
|---|---|
| Product Type | Parameters |
| Product Line | GPD |
| Part Number | GPD-505-Listing-of-Parameters |
| n001 | Init/Control Mode |
| n002 | Run/Stop Source |
| n003 | Input Voltage Selection |
| n006 | Reverse Run Enable |
| n010 | V/f Pattern Selection |
| n017 | Min Frequency (n017) |
| n018 | Max Frequency (n018) |
| n019 | Acceleration Time (n019) |
| n020 | Deceleration Time (n020) |
| n024 | Display Scaling Mode (n024) |
| n032 | Motor Rated Current (n032) |
| n050 | PWM Carrier Frequency (n050) |
| n064 | DC Brake Level (n064) |
| n066 | DC Brake Time (n066) |
The GPD-505-Listing-of-Parameters by Yaskawa acts as a resource for precise parameter configuration of the GPD series. This set of parameters includes several critical control options that ensure the drive operates according to the desired specifications.
Key settings like n001 (Init/Control Mode) enable selection of the initial operation mode. Meanwhile, n002 (Run/Stop Source) determines the method for stopping or starting the motor, providing flexibility for integration into different applications. Input voltage selection, referenced as n003, allows for adaptation based on the power supply type.
To facilitate reversing capabilities, n006 enables reverse run functionality when necessary. The V/f pattern selection, indicated by n010, defines the relationship between voltage and frequency, which is essential for varying application needs.
Parameters n017 and n018 set the minimum and maximum frequency limits, respectively. These controls help maintain operational efficiency by ensuring the motor runs within safe frequency boundaries. Additionally, parameters n019 and n020 dictate acceleration and deceleration times, allowing for smooth transitions between speeds, thus enhancing performance and reducing mechanical stress.
The display scaling mode, controlled by n024, provides visual feedback on parameter readings for user convenience. Motor rated current is specified by n032, ensuring that the configuration aligns with motor specifications. The PWM carrier frequency parameter (n050) influences drive performance and efficiency, while n064 and n066 handle DC brake settings, including brake level and duration, further enhancing motor control during stops. This comprehensive listing aids in achieving optimal performance for Yaskawa's GPD series.