Yaskawa GPD GPD-505-Simplified-Startup

Product image is representative; revision or series may vary. Contact us to request a specific version.

GPD-505-Simplified-Startup

|

The GPD-505-Simplified-Startup by Yaskawa is a start-up procedure that facilitates the commissioning of motor drives. This method utilizes default settings for fast initialization, accommodating various configurations for operational settings.

Call for an immediate quote
2 Year DO Supply Warranty
Available
Ships from Raleigh, NC
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for GPD-505-Simplified-Startup

ManufacturerYaskawa
Product TypeStart-Up Procedure
Product LineGPD
Part NumberGPD-505-Simplified-Startup
Startup ModeQuick setup using default parameters
Initial ParameterSet n001, that is 0 or 1 (2-wire or 3-wire)
Motor Rated CurrentSet n032 to motor’s FLA
Min/Max FrequencySet n017 and n018 as needed
Accel/Decel TimeAdjust n019 / n020
Start/Stop SourceSet n002 (keypad, terminals, etc.)
Speed Reference SourceSet n003 (analog, keypad, preset)
V/f PatternSelect using n010 (standard/custom)
Run CommandMethod via keypad or digital input
Direction ControlEnable/disable reverse via n006
Output CheckVerify motor rotation & speed
Stall PreventionEnable via n070–n072
Display ScalingSet n024 (e.g., Hz, RPM)

Yaskawa's GPD-505-Simplified-Startup is designed to streamline the process of starting up motor drives. This procedure is particularly beneficial for users looking to implement a straightforward commissioning of their systems. With a design focused on simplicity, it allows for quick setups using default parameters to minimize the time and effort required for initial configurations.

Beginning with the initial parameter, users should set n001 to either 0 or 1, depending on whether a 2-wire or 3-wire configuration is being utilized. The motor's full-load amperage (FLA) can be entered into n032, ensuring that the drive's capabilities align with the motor's specifications. To establish the desired operational range, the minimum and maximum frequencies can be set through n017 and n018 respectively.

For adaptability, the acceleration and deceleration times are adjustable via parameters n019 and n020, which can be fine-tuned to match the required application needs. The user can specify the start/stop control source by adjusting n002, allowing for inputs from the keypad or external terminals. Similarly, n003 offers a choice of speed reference inputs—these can be derived from analog signals, keypad commands, or preset values.

Furthermore, users can select a voltage/frequency pattern with parameter n010, allowing for either a standard or custom profile. The drive can be commanded to run through keypad inputs or digital signals, based on the required operational command structure. Direction control can be enabled or disabled by manipulating n006, offering the flexibility to reverse motor direction when necessary. It’s crucial to verify both motor rotation and speed to ensure proper functionality. This check can be done as part of the output validation process. Moreover, to prevent stalling, stall prevention features can be activated using parameters n070 through n072. Lastly, the display scaling can be set to show real-time information, such as Hz or RPM, via n024, providing important feedback regarding performance during operation.