Product image is representative; revision or series may vary. Contact us to request a specific version.
The Yaskawa GPD-515-G5-Initial-Start-up is an AC drive start-up module, designed to facilitate the initial setup of motors. It supports manual configuration or keypad-guided procedures to begin operations efficiently.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Yaskawa |
|---|---|
| Product Type | AC Drive Start-up Module |
| Product Line | GPD |
| Part Number | GPD-515-G5-Initial-Start-up |
| Start-up Mode | Manual or keypad-guided setup |
| Input Power Check | Verify correct 3-phase supply |
| Rated Motor Voltage | Set parameter n081 |
| Rated Motor Current | Set parameter n082 |
| Rated Motor Frequency | Set parameter n083 |
| Rated Motor Speed | Set parameter n084 |
| Output Frequency Range | Set n008 (min) and n009 (max) |
| Start/Stop Command Source | Set parameter n002 (terminal, keypad, etc.) |
| Speed Reference Source | Set parameter n003 (analog, digital) |
| Motor Rotation Test | Run test to verify direction |
| Accel/Decel Time | Set n010 and n011 (in seconds) |
| Torque Boost | Enable or disable via n088 |
| Display Units | Set display scaling via n024 |
| Error Check | Ensure no fault codes during run test |
The GPD-515-G5-Initial-Start-up by Yaskawa acts as an essential tool for configuring AC drives. Users can initiate the application either manually or through a guided setup via the keypad, which simplifies the start-up process. It includes essential checks such as verification of the three-phase input power supply to ensure safe and correct operation.
Key parameters like rated motor voltage, current, frequency, and speed are adjusted through specific settings (n081, n082, n083, and n084, respectively), making customization straightforward. The output frequency range is designated by setting parameters n008 for the minimum and n009 for the maximum limits, catering to different operating conditions.
Control can be executed from various sources, with command source settings available through parameter n002, allowing options such as terminal control or keypad initiation. The speed reference can be configured to use either analog or digital inputs via parameter n003.
A critical feature is the motor rotation test, which ensures the motor spins in the correct direction. Parameters n010 and n011 define acceleration and deceleration times in seconds, allowing the drive's operational response to be accurately tuned to requirements. Torque boost can be enabled or disabled via parameter n088, enhancing performance under specific conditions.
The display units can be adjusted for scaling purposes through parameter n024, contributing to user-friendly operation. Lastly, during any run test, an error check is performed to ensure that no fault codes are present, thereby affirming operational integrity throughout the start-up phase.