Technical specifications for GPD-515-G5-Initial-Start-up

ManufacturerYaskawa
Product TypeAC Drive Start-up Module
Product LineGPD
Part NumberGPD-515-G5-Initial-Start-up
Start-up ModeManual or keypad-guided setup
Input Power CheckVerify correct 3-phase supply
Rated Motor VoltageSet parameter n081
Rated Motor CurrentSet parameter n082
Rated Motor FrequencySet parameter n083
Rated Motor SpeedSet parameter n084
Output Frequency RangeSet n008 (min) and n009 (max)
Start/Stop Command SourceSet parameter n002 (terminal, keypad, etc.)
Speed Reference SourceSet parameter n003 (analog, digital)
Motor Rotation TestRun test to verify direction
Accel/Decel TimeSet n010 and n011 (in seconds)
Torque BoostEnable or disable via n088
Display UnitsSet display scaling via n024
Error CheckEnsure no fault codes during run test

The GPD-515-G5-Initial-Start-up by Yaskawa acts as an essential tool for configuring AC drives. Users can initiate the application either manually or through a guided setup via the keypad, which simplifies the start-up process. It includes essential checks such as verification of the three-phase input power supply to ensure safe and correct operation.

Key parameters like rated motor voltage, current, frequency, and speed are adjusted through specific settings (n081, n082, n083, and n084, respectively), making customization straightforward. The output frequency range is designated by setting parameters n008 for the minimum and n009 for the maximum limits, catering to different operating conditions.

Control can be executed from various sources, with command source settings available through parameter n002, allowing options such as terminal control or keypad initiation. The speed reference can be configured to use either analog or digital inputs via parameter n003.

A critical feature is the motor rotation test, which ensures the motor spins in the correct direction. Parameters n010 and n011 define acceleration and deceleration times in seconds, allowing the drive's operational response to be accurately tuned to requirements. Torque boost can be enabled or disabled via parameter n088, enhancing performance under specific conditions.

The display units can be adjusted for scaling purposes through parameter n024, contributing to user-friendly operation. Lastly, during any run test, an error check is performed to ensure that no fault codes are present, thereby affirming operational integrity throughout the start-up phase.