Free UPS Ground on All Orders!
+1 (919) 205-4392
Yaskawa GPD GPD-515-G5-Simplified-Startup

Product image is representative; revision or series may vary. Contact us to request a specific version.

GPD-515-G5-Simplified-Startup

|

The GPD-515-G5-Simplified-Startup by Yaskawa is an AC drive start-up module emphasizing straightforward installation and configuration. It features a digital operator for basic parameter setup and supports start commands through digital terminals or a keypad.

Call for an immediate quote
2 Year DO Supply Warranty
Available
Ships from Raleigh, NC
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for GPD-515-G5-Simplified-Startup

ManufacturerYaskawa
Product TypeAC Drive Start-up Module
Product LineGPD
Part NumberGPD-515-G5-Simplified-Startup
Startup ModeBasic parameter setup via digital operator
Start Command Sourcen002 = 1 (digital terminals) or 3 (keypad)
Speed Reference Sourcen003 = 2 (analog input) or 3 (keypad)
Motor Rated Voltagen081 = [Motor Nameplate Voltage]
Motor Rated Currentn082 = [Motor Nameplate Current]
Motor Rated Frequencyn083 = [Typically 50/60 Hz]
Motor Rated Speedn084 = [Motor RPM]
Output Frequency Limitsn008 = Min, n009 = Max
Acceleration Timen010 = [e.g., 10 sec]
Deceleration Timen011 = [e.g., 10 sec]
Display Unitsn024 = Hz or RPM
Torque Boostn088 = 0 (off) or 1–3 (manual/auto boost)
Stall Preventionn092–n094 = Enable if needed
Test RunCheck motor direction, adjust if reversed

Yaskawa's GPD-515-G5-Simplified-Startup serves as a module specifically designed for AC drive initiation. This device encompasses a digital operator that streamlines the setup process for basic parameters. For starting commands, users can select between digital terminals or utilize the keypad. Additionally, the module accommodates speed references coming from either an analog input or directly from the keypad.

Users can easily configure important motor parameters such as the rated voltage (n081), current (n082), and frequency (n083). Furthermore, the rated speed (n084) can be specified, ensuring the motor operates within the desired performance metrics. It supports setting limits for output frequency, allowing for fine control over operational ranges.

The module provides customizable acceleration (n010) and deceleration times (n011), enabling tailored control of motor speed changes. Display units can be adjusted to read out frequency in Hz or motor speed in RPM based on user preference. Furthermore, torque boost settings (n088) can either be disabled or set within specific ranges to enhance performance as necessary. Stall prevention settings (n092-n094) can be activated if required to safeguard the motor operation during low torque scenarios.

Before finalizing setup, users are encouraged to conduct a test run to confirm the motor direction. Adjustments should be made if the motor is found to be running in reverse. Overall, the GPD-515-G5-Simplified-Startup module offers practical functionalities that simplify the commissioning of Yaskawa AC drives, allowing effective control and monitoring in a wide range of applications.