969 results
Honeywell / Other
This valve operates on a voltage of 110/120 V AC and supports both 50 and 60 Hz input frequencies. It features a normally-closed safety shutoff configuration, ensuring secure closing under standby conditions. It draws a current of 0.525 A, and its NPT thread type allows for reliable connections.
Honeywell / Other
This component features an IP 65 enclosure rating, providing robust protection against dust and water. The assembly weighs 8.36 lbs and includes a 2-inch NPT internal threaded pipe connection, facilitating seamless integration into gas systems. The valve operates with a size 2 configuration, utilizi
Honeywell / Other
Designed for effective operation, this module supports flame monitoring through ionization electrode or UV sensors, with options for intermittent or continuous operation. It accommodates a maximum output contact current of 2 A per output, with a total of 2.5 A combined. Additionally, the unit can be
Honeywell / Other
This controller maintains an operating temperature range from -20°C to 50°C and can handle ambient humidity levels from 0% to 95% RH without condensation. It can support three RS-485 channels and connect up to 96 transmitter inputs. Communication options include Modbus RS-485 and optional BACnet/IP,
Honeywell / Other
This transducer is temperature compensated across a range of 15°C to 71°C and exhibits a high degree of accuracy with ±0.10% full scale measurement. The device also features linearity and hysteresis ratings of ±0.10% and ±0.05% full scale, respectively. Its robust construction includes a case made f
Honeywell / Other
Weighing in at 1.76 lbs, this transmitter supports a humidity range of 0-90% RH without condensation. The housing is finished in black, built from painted steel, ensuring durability. The MIDAS-T-004 operates with a maximum power consumption of approximately 5.0 W (12.95 W with pyrolyzer).
Honeywell / Other
This load cell exhibits a non-linearity accuracy of ±0.1% of full scale and a hysteresis of ±0.08%. It operates effectively within a temperature range of -54°C to 121°C, with temperature compensation guaranteed between 15°C and 71°C. The output signal is non-amplified, providing 3 mV/V ±0.5% FS, sui
Honeywell / Other
This unit weighs 0.89 lbs and boasts an IP67 rating, ensuring protection against dust and water. It operates effectively within a temperature range of -20°C to 50°C and can be stored between -40°C and 70°C. With a humidity tolerance of up to 95% RH, this scanner is well-suited for challenging enviro
Honeywell / DR4500
Designed to accommodate multiple input types across three channels, this recorder allows for T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA inputs. It employs a standard pen for recording data, with mounting options available for panel, 2-inch pipe, or surface installations. Operating relative humidity
Honeywell / DR4500
This circular chart recorder is equipped with three input channels that can handle T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA signals. The operating temperature range extends from 0 °C to 55 °C, ensuring functionality in various environments. Mounting options consist of panel, 2-inch pipe, and surfa