988 results
Eaton Cutler-Hammer / PLCs / CCV Series
This circuit breaker operates with a thermal magnetic trip unit, providing dual protection features. It supports an interrupt rating of 25 kA at 240 Volts AC and has a wide wire size range from 2/0 AWG to 300 kcmil. This UL-certified breaker can be mounted via bolt-on or plug-in methods, making it f
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This device employs a fixed thermal and magnetic trip type (T186) and operates efficiently at frequencies of 50/60 Hz. The F-frame construction allows for a maximum interrupting capacity of 35 kAIC at 480 Vac, and 65 kAIC at 240 Vac, ensuring effective performance during fault conditions. With load
Eaton Cutler-Hammer / PLCs / Pow-R-Way III
This unit features a plug-in connection type that simplifies the installation process. It consists of three poles and includes overcurrent and fusible protection mechanisms. Compliant with NEMA standards, it also meets multiple certifications including UL 857, CSA, ANSI, and IEEE. This unit incorpor
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
The NGH312036EC model is configured with three poles and utilizes LSIG trip technology to safeguard electrical circuits. It is rated for 100% of its capacity and accommodates line and load connections. The interrupting ratings are listed as 100 kAIC at 240V and 65 kAIC at 480V, verifying its effecti
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
Equipped with a NG frame, this circuit breaker has a maximum interrupting rating of 200 kAIC at 240V and 100 kAIC at 480V. It is a complete unit with line and load terminals and is HACR rated. This product meets UL and CSA certification requirements.
Eaton Cutler-Hammer / PLCs / BR Circuit Breakers
This circuit breaker has a common trip type and includes three poles. With an interrupt rating of 22 KAIC, it ensures effective circuit protection. The BRH3100 operates optimally in humidity levels of 80% and can withstand storage temperatures between 0°C and 40°C.
Eaton Cutler-Hammer / PLCs / Power Defense
This two-pole circuit breaker includes thermal magnetic protection and features a feed-thru connection type. Rated for 25kA at 480 V, it offers dependable fault interruption. The frame type is designated as PGD, and the trip type follows the T298 configuration, supporting standard line and load term
Eaton Cutler-Hammer / PLCs / Power Defense
This circuit breaker supports single-phase systems and has an AIC rating of 25 kA at 480 V. It is designed for feed-thru connections and functions effectively in environments with humidity levels up to 80%. Suitable for installations at altitudes of up to 1000 meters above sea level, this model can
Eaton Cutler-Hammer / PLCs / BR Circuit Breakers
This circuit breaker has two poles and offers a 20 kAIC interrupt rating. A common trip mechanism activates both poles simultaneously, enhancing safety during fault conditions. It features a trip sensitivity of 5 mA and accommodates wire sizes ranging from 14 to 4 AWG. Mounting is facilitated throug
Eaton Cutler-Hammer / PLCs / QuickLag
This circuit breaker is built with a BAB frame type and is designed for bolt-on mounting. It supports long-time and instantaneous trip functions and has a toggle actuator for easy operation. The shunt trip voltage can be configured for 24/48 VDC or 120/240 VAC, depending on the selected accessory. W