1289 results
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
The NGC312036EC circuit breaker includes three poles and operates within a frequency range of 50 to 60 Hz. It features a T172 trip type and utilizes both line and load terminal connections. This unit has impressive interrupt ratings, reaching 200 KAIC at 240 VAC and 100 KAIC at 480 VAC.
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This shunt trip unit is compatible with RG-frame models and mounts on the right side. It features pigtail leads for connection and supports both 24 VAC and 24 VDC control voltages. With an operating frequency ranging from 50 to 60 Hz, it also provides protection from residual ground faults and 30 mA
Eaton Cutler-Hammer / PLCs / BR Circuit Breakers
This circuit breaker features two poles and is designed for single-phase systems. It utilizes a common trip type with thermal magnetic protection. The BRH290 can handle interruptions up to 22 KAIC, ensuring reliable operation under fault conditions. It includes long-time and instantaneous trip funct
Eaton Cutler-Hammer / PLCs / Power Defense
This molded case circuit breaker, part of the Power Defense series, features a thermal magnetic trip unit. It includes three poles and a feed-thru connection type, making it versatile for various configurations. The interrupt rating of 25 kiloamperes at 480 volts AC ensures robust protection during
Eaton Cutler-Hammer / PLCs / Power Defense
This circuit breaker features three poles and a Size 2 frame. It is classified as Class A and is certified by UL and CSA standards. The interrupting rating is 25 kAIC at 480V, and the trip system utilizes fixed thermal and magnetic mechanisms. It operates effectively in ambient temperatures from 32
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This three-pole circuit breaker, featuring an EG frame, provides various interrupting ratings: 65 kAIC at 480 Vac, 100 kAIC at 240 Vac, and 35 kAIC at 600Y/347 Vac. The EGH3060FFB operates within a frequency range of 50/60 Hz and is suitable for HACR applications. It has a rated insulation voltage o
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This circuit breaker features a thermal magnetic mechanism with a fixed trip unit. It consists of three poles, allowing for effective branch circuit protection in 3-phase systems. The line-side is terminated using a busbar, while lugs are used for load-side connections. Compliance with UL, CSA, and
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This circuit breaker features three poles and incorporates both thermal and magnetic trip functions. It is compliant with UL and CSA standards and has an interrupt rating of 25 kAIC at 240 VAC and 18 kAIC at 480 VAC. The unit has a fixed trip mechanism and utilizes a bolt-on connection type.
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This circuit breaker features a three-pole design and is compatible with R frame circuit breakers. It can operate in temperatures ranging from 0°C to 40°C and is rated for a maximum humidity level of 80% (non-condensing). The SNT6P11K is also suitable for installation at altitudes up to 1000 meters