404 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The device has a robust interrupt capacity of 65 kiloamperes at 240 Volts AC and is configured with three poles. The thermal magnetic trip unit offers both long-time and instantaneous trip functions for enhanced protection. It is suited for panel mounting and is equipped with a toggle actuator for u
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is part of the Series C lineup and operates within a frequency spectrum of 50 to 60 Hertz. It has a thermal magnetic trip type classified as T186 and utilizes load side terminals for connectivity. The interruption capacity is rated at 14 kAIC for 240 V and 18 kAIC for 480 V, ens
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker has a single pole and an interrupt rating of 14 kAIC at 480 V, and an interrupt capacity of 18 kAIC at 240 V, providing robust performance under fault conditions. It is rated for 50/60 Hz frequency and features a load-side connection type to facilitate integration into existing
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This standalone molded case circuit breaker operates with 90 amperes and features two poles. It employs thermal magnetic protection, enhancing safety by providing reliable trip functionality. With a significant interrupt rating of 65 kA at 240 V, it is capable of managing fault conditions effectivel
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This model fits in the Series C Circuit Breakers and has a frame type designated as F. It supports voltages up to 600 VAC and 250 VDC while providing significant interrupt ratings. The breaker can interrupt 18 kA at 240 VAC and maintains a consistent performance with 14 kA at both 480 VAC and 600 VA
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This Series C circuit breaker features two poles and operates under a trip type T186. It is capable of withstanding interrupt ratings of 14 kAIC at 480 VAC and 18 kAIC at 240 VAC. Its operation is supported within frequency limits of 50 to 60 Hz, suitable for diverse applications.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This rating plug is compatible with J-K frame types. It operates efficiently within a temperature range of 0°C to 40°C, making it suitable for standard applications. The unit can also operate at an installation altitude of up to 1000 MSL and maintain operational functionality in humidity levels up t
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The A1L2LPK is designed to mount on the left side and is compatible with J frame types. This product functions within a temperature range of 0°C to 40°C and supports both operating and storage humidity up to 80% non-condensing. Installation is feasible at altitudes of up to 1000 meters above sea lev
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This unit comprises two poles and is intended for load side terminal connections. It functions effectively across a frequency range of 50 to 60 Hz and falls under the F frame type category. The EDH2125 breaker is equipped to handle substantial electrical loads while maintaining safety and compliance
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker has a frame type of F and comprises two poles. It is rated for 240 VAC and 125 VDC. It exhibits an impressive interrupt rating of 100 KAIC at 240 VAC, providing reliable protection against fault conditions. The unit utilizes a T186 trip type and operates effectively across a fre