1222 results
Allen Bradley / PLCs / 140G MCB
This Allen Bradley molded case circuit breaker, 140G-H15C4-C60, is built with a frame type H and supports up to four poles. It manages a current range of 60 A and boasts an outstanding interrupting rating of 150 kA. It functions effectively under a rated insulation voltage of 1000 V and withstands i
Allen Bradley / PLCs / 140G MCB
This circuit breaker is constructed with a frame classified as M and is capable of managing a current of 800 A. Rated for insulation of 1000 volts, it also withstands impulse voltages of up to 8 kV. The device's weight is 26.68 pounds, indicating a solid build. It operates at a mechanical life of 12
Allen Bradley / PLCs / 140G MCB
This circuit breaker operates with a rated current range up to 160 A and provides an insulation voltage rating of 1000 volts. It withstands impulse voltages of up to 8 kV. Weighing in at 2.65 lb, it offers a mechanical life of 240 operations per hour and an electrical life of 120 operations per hour
Allen Bradley / PLCs / 140G MCB
This circuit breaker has three poles and utilizes a thermal magnetic trip unit with a fixed magnetic trip. It includes essential accessories such as an auxiliary switch and a mechanical trip indicator, providing enhanced operational feedback. The device comes certified under UL 489, CSA, and IEC sta
Allen Bradley / PLCs / 140G MCB
This unit is classified under the H-frame and supports a current range of up to 32 Amps. With an impressive interrupting capacity of 100 kA, it ensures effective protection against short circuits. The rated insulation voltage of 1000 V and impulse withstand voltage of 8 kV further enhance its robust
Allen Bradley / PLCs / 140G MCB
The 140G-G3C4-C40 is a four-pole molded case circuit breaker rated at 125 Amps. It features fixed thermal and magnetic protection options with a current range of 40 Amps. The device handles an interrupting capacity of 35 kA and supports an insulation voltage of 800 V. With an impulse withstand ratin
Allen Bradley / PLCs / 140G MCB
This molded case circuit breaker supports an adjustable thermal protection mechanism alongside fixed magnetic protection. The 140G-G3E4-D16 model operates within a current range of 160 Amps and has a thermal trip set at 160 Amps. Additionally, it is rated for insulation voltages up to 800 Volts and
Allen Bradley / PLCs / 140G MCB
This circuit breaker operates within the JC frame type and has a rated insulation voltage of 1000 volts. It also features an impulse withstand rating of 8 kV. The device weighs 5.51 pounds and supports a mechanical longevity of 240 operations per hour alongside an electrical operational capacity of
Allen Bradley / PLCs / 140G MCB
This molded case circuit breaker features a frame size of I and operates effectively within a current range of 160 A. Its rated insulation voltage is 800 V, while the impulse withstand voltage is rated at 8 kV. The protection system employs fixed thermal and fixed magnetic mechanisms. The 140G-I2C3-
Allen Bradley / PLCs / 140G MCB
This molded case circuit breaker operates at an interrupting rating of 100 kA and is built with a frame type H. It includes fixed thermal and magnetic protection, operating in a current range of 16 Amps. With a rated insulation voltage of 1000 V and an impulse withstand voltage of 8 kV, it ensures r