714 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This electronic molded case breaker is structured with a frame type designated as F. It features three poles and is compliant for operation between 50 Hz and 60 Hz. At 240 VAC, it has an interrupting capacity of 65 kAIC and 35 kAIC at 480 VAC. This device is suitable for both AC and DC applications,
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker showcases a voltage rating of 600V AC and 250V DC. With an interrupting capacity of 65 kAIC at 240 VAC, 35 kAIC at 480 VAC, and 18 kAIC at 600 VAC, it ensures robust performance during fault conditions. The device supports long-time, short-time, and ground fault trip functions,
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit protection device features a line and load terminal configuration. It offers a substantial interrupting capacity of 65 kAIC at 240 VAC and 35 kAIC at 480 VAC. Using an Electronic Digitrip 310 RMS, this unit enhances reliability and performance.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
As part of the Series C Circuit Breakers, this unit features three poles and is constructed within a J-Frame. It employs fixed thermal and magnetic trip types, ensuring stable performance during load variations. The interrupting capacity is rated at 100 kAIC for 240 VAC, 65 kAIC for 480 VAC, and 25
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This unit features a three-pole configuration and is classified as an F-frame type circuit breaker. The electronic LS trip unit provides both long-time and short-time protection, supported by the Digitrip 310 RMS technology. It has interrupting ratings of 65 kAIC at 240 VAC, 35 kAIC at 480 VAC, and
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This unit operates with three poles and is rated to interrupt currents of 65 kAIC at 480 VAC. The thermal magnetic trip mechanism includes both fixed thermal and fixed magnetic types. Its frequency range is compliant within 50 Hz to 60 Hz, making it suitable for standard electrical systems.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This molded case circuit breaker belongs to the Series C line and is classified as a type HFD. It includes three poles and is housed in an F-frame. The device is equipped with fixed thermal trip technology and has an interrupt rating of 42 kAIC at 600 V. The terminals are configured for both line an
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This HFD series circuit breaker features a three-pole configuration suitable for 50/60 Hz frequency operations. It functions well within a voltage range of 600 V AC and 250 V DC. The trip unit, model T186, utilizes a thermal-magnetic technology with a fixed thermal trip. Its interrupt ratings stand
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This motor circuit protector is shaped for three-pole configurations and comes with a NEMA 4 enclosure that ensures adequate protection in industrial settings. It is equipped with an auxiliary switch and supports shunt trip voltages of 48-127 V or 48-60 V DC. Rated for temperatures between -20°C and
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This three-pole circuit breaker is designed for surface-mounting and offers a trip type of T186 with a shunt trip option rated at 120V. The unit operates efficiently at frequency ratings of 50/60 Hz and is capable of handling high interrupt ratings of 14 kAIC at 480Y/277 Vac and 65 kAIC at 240 Vac.