Eaton Cutler-Hammer / Drives / W200 Drives
This motor controller is designed for reversing applications and supports horizontal mounting orientations. It features functionality for soft starting, speed control, and torque control. The device is suitable for environments with operating temperatures ranging from 0 to 40 degrees Celsius, and it
Eaton Cutler-Hammer / Drives / W200 Drives
This NEMA contactor comes with a three-pole configuration and is designed for a motor voltage of 230 volts. Its operational temperature ranges from 0°C to 40°C, and it can be stored within -30°C to 70°C. The device is rated for installation at altitudes up to 2000 meters and can handle relative humi
Eaton Cutler-Hammer / Drives / W200 Drives
Designed for 3-phase operation, this NEMA Size 2 starter supports a coil voltage of 230 VAC. It is rated for horsepower capacities of up to 10 Hp at 200 VAC, 15 Hp at 230 VAC, and 25 Hp at 460V/575 VAC. The starter operates within a frequency range of 50 Hz to 60 Hz and is intended for vertical moun
Eaton Cutler-Hammer / Drives / W200 Drives
This vacuum starter is NEMA size 4 rated and operates effectively at rated voltages of up to 600 VAC. With a coil voltage requirement of 110 to 120 V AC, this unit is suitable for various power systems and supports both 50 and 60 Hz frequencies. It offers a horsepower rating of 40 Hp at 200 V, reach
Eaton Cutler-Hammer / Drives / S801 Soft Starters
This model operates inside the delta configuration and features three poles. With an insulating voltage rating of 660V, it supports a maximum alternating current of 240V and direct current of 120V. The mechanical lifespan of the bypass component is rated at 10 million operations, ensuring reliabilit
Eaton Cutler-Hammer / Drives / S801 Soft Starters
This soft starter operates at a maximum AC voltage of 240 volts and a maximum DC voltage rating of 120 volts. It is a non-combination type with three poles suitable for inside delta applications. It can handle an operating frequency ranging from 47 to 63 Hz. The mechanical lifespan of the bypass is
Eaton Cutler-Hammer / Drives / S811 Soft Starters
The Eaton Cutler-Hammer S811V72P3S soft starter has an operating voltage range of 200 to 600 volts and a maximum current capacity of 720 amps. It is designed to operate in standard applications with a frequency range of 47 to 63 Hz. The device has a high insulation voltage rating of 660 V and is res
Eaton Cutler-Hammer / Drives / W201 Contactors
The W211K2CN model features 3-pole connections and is rated for a continuous current of 45 amps. It has a coil voltage of 110V at 50 Hz and conforms to NEMA Size 2 specifications. The dimensions of this contactor are 2.5 inches wide, 6.5 inches high, and 4.84 inches deep.
Eaton Cutler-Hammer / Drives / S811+ Soft Starters
This non-combination soft starter operates at a maximum of 240 volts AC and 120 volts DC, with an insulating voltage of 660V. The device features three poles and supports an operating frequency from 47 to 63 Hz. The mechanical bypass is rated for a lifespan of 10 million operations and can withstand
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Equipped with fixed thermal and fixed magnetic trip units, this circuit breaker provides reliable protection against overloads and short circuits. The interrupting ratings vary based on voltage levels: 100 kAIC at 240 VAC, 65 kAIC at 480 VAC, 25 kAIC at 600 VAC, and 22 kAIC at 250 VDC. Constructed t