3165 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
As a three-pole circuit breaker, the KD3400F allows for effective protection in three-phase systems. It features a frequency rating of 50/60 Hz and supports an interrupt rating of 35 kAIC at 480 VAC and 65 kAIC at 240 VAC. This breaker is UL listed for safety and features a K frame design.
Eaton Cutler-Hammer / PLCs / QuickLag
This device is a 2-pole ground fault circuit breaker with an interrupt rating of 10 kAIC and a common trip type. Its trip sensitivity is set at 5 mA, ensuring effective fault detection. The unit supports bolt-on mounting and can accommodate wire sizes of #14–10 AWG for copper and #12–10 AWG for alum
Eaton Cutler-Hammer / Drives / S811 Soft Starters
This soft starter features a frame size of 290 mm and can manage a maximum current capacity of 500 amps. Its insulating voltage rating is 660 V, enabling robust operations across varied environments. The device operates within a frequency range of 47 to 63 Hz. An extended ramp start function enhance
Eaton Cutler-Hammer / Drives / W201 Contactors
Designed as a reversing vertical contactor, the W251K2CF handles a voltage of 200 volts and can manage up to 45 continuous amps. It has dimensions of 2.5 inches wide, 6.5 inches high, and 4.84 inches deep, with a weight of 2 pounds. This contactor comes with three poles and operates on a coil voltag
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
Designed for use with NG-frame circuit breakers, the SNT5LP18K features three poles and supports a current rating of 1200 A. The operational AC voltage ranges from 480 to 600 VAC, and is connected via pigtail leads. It is optimized for left-sided mounting and is compatible with ND type frames.
Eaton Cutler-Hammer / Drives / SVX 9000 Drives
This drive is suitable for 3-phase input power and supports a supply frequency of 50/60 Hz. It features an internal brake chopper circuit and allows for modification via standard boards. The interface is managed via an alphanumeric keypad. It provides a total of 8 inputs (2 analog and 6 digital) and
Eaton Cutler-Hammer / Drives / S801 Soft Starters
With a rating of 420 amps, the S801V42N3D soft starter is suitable for three-pole configurations and operates within a frequency range of 47 to 63 Hz. The maximum insulation voltage is 660 volts. This model is classified as an inside-the-delta starter and has a mechanical bypass lifespan of 10 milli
Eaton Cutler-Hammer / Drives / S801 Soft Starters
This soft starter operates with three poles and is suitable for use within an operating frequency range of 47 to 63 Hz. Its maximum insulating voltage is rated at 660 volts. The bypass mechanism is designed for 10 million cycles, ensuring durability. It allows for a maximum AC voltage of 240 volts a
Eaton Cutler-Hammer / Drives / S811 Soft Starters
This soft starter operates within a voltage range of 200 to 600 volts and is optimized for 47 to 63 Hz operation. It features a maximum current capacity of 180 amps and a frame size of 200 mm. The S811T18P3S has a 230V horsepower rating of 60 and withstands insulating voltages of 660 V. Additionally