3165 results
Eaton Cutler-Hammer / Drives / S811+ Soft Starters
This soft starter implements a 290 mm frame size and operates effectively with three poles. The unit manages AC voltages up to 240 volts and DC voltages up to 120 volts. It maintains an insulating voltage of 660 volts and supports an operating frequency range of 47-63 Hz. The starter's mechanical by
Eaton Cutler-Hammer / PLCs / QuickLag
This circuit breaker is constructed to handle one pole and operates within a voltage range of 120 VAC. It includes a thermal magnetic protection system with long-time and instantaneous trip functions. With a 10 kAIC interrupt rating at 120 VAC, it ensures effective fault protection. Designed to be m
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This molded case circuit breaker features an electronic Digitrip 310 RMS trip unit that allows for various trip functions, including long-time, short-time, and instantaneous settings. It has a high interrupting capacity with ratings of 100 kAIC at 240 VAC, 65 kAIC at 480 VAC, and 35 kAIC at 600 VAC,
Eaton Cutler-Hammer / Drives / S801 Soft Starters
This open soft starter is part of the S801 lineup and features a non-combination design. It supports an operating frequency range of 47-63 Hz and is rated for a maximum AC voltage of 240 volts and a maximum DC voltage of 120 volts. The insulating voltage is rated at 660V, ensuring resilience against
Eaton Cutler-Hammer / Drives / S811+ Soft Starters
This soft starter, part of the S811+ series, is designed to manage motors up to 500 amps and operates at a voltage rating of 240 volts AC and 120 volts DC. It features three poles and comes with a premium option rated for 690 volts. The unit is constructed with an insulating voltage of 660 volts and
Eaton Cutler-Hammer / PLCs / BW Breakers
This main circuit breaker features a compact design with a two-pole configuration and is intended for installation in MHM/MHR load centers. It has a thermal-magnetic trip mechanism and a short-circuit rating of 25kA at 240V. The device is compatible with wire sizes ranging from #2 AWG up to 300 kcmi
Eaton Cutler-Hammer / Drives / SVX 9000 Drives
This adjustable frequency drive is classified under the open drives family and features an internal brake chopper circuit. It accepts input from 3-phase systems and follows EMC H standards. The frame size is denoted as FR4, and it comprises 2 analog inputs along with 6 digital inputs, while offering
Eaton Cutler-Hammer / Drives / SVX 9000 Drives
This Eaton adjustable frequency drive serves multiple functions. It supports 3-phase input under the EMC H standard. The drive's NEMA Type 12 enclosure enhances protection in diverse environments. The I/O configuration includes two analog and six digital inputs, one analog output, one digital output
Eaton Cutler-Hammer / Drives / S801 Soft Starters
This non-combination soft starter is configured for three poles and designed for 'inside the delta' installations. Rated for an insulating voltage of 660V, it supports AC up to 240 volts and DC up to 120 volts. The bypass mechanism has a mechanical lifespan of 10 million operations, ensuring durabil