STD720-E1HS4AS-1-A-AHA-11S-A-30A0-00-0000

STD720-E1HS4AS-1-A-AHA-11S-A-30A0-00-0000

Honeywell / SmartLine

This differential pressure transmitter includes a maximum turndown ratio of 100:1. The URL is set at 400/1000 mbar, while the LRL measures from -400 to -1000 mbar. It implements a 4-20mA DC analog output and utilizes silicone oil 200 as the fill fluid, ensuring reliable operation.

Call
2000-050-090-126-000-20-000000-0-0-0

2000-050-090-126-000-20-000000-0-0-0

Honeywell / HercuLine 2000

This actuator features a basic motor without electronic components, ensuring straightforward operation. It offers a torque output of 6.0 Nm and operates at an input frequency of 60 Hz. The device includes two auxiliary switches and utilizes a 3-wire drive for up and down movements. The Honeywell uni

Call
STD720-E1AC4AS-1-A-AH0-11C-A-10A0-00-0000

STD720-E1AC4AS-1-A-AH0-11C-A-10A0-00-0000

Honeywell / SmartLine

Designed for a temperature range of -40 to 85 °C, this transmitter provides accurate readings with a maximum turndown ratio of 100:1. Employing both 316 stainless steel for the process head and diaphragm ensures durability. With an operational range extending from -400 to 1000 mbar, this device feat

Call
DR45A1-1000-00-000-0-000000-0

DR45A1-1000-00-000-0-000000-0

Honeywell / DR4500

Designed specifically for the DR4500 series, this circular chart recorder is equipped with one standard pen and comes with a gray door and glass window. It operates in a temperature range from 0 °C to 55 °C and supports minimal relative humidity levels of 5% (non-condensing).

Call
DC2800-CB-1F0-220-100-00-0

DC2800-CB-1F0-220-100-00-0

Honeywell / UDC2800

Operating as a digital controller within the UDC2800 series, this unit handles inputs from thermocouples, RTDs, and multiple voltage and current types. With CE, UL, and CSA certifications, it meets essential compliance standards. The controller features outputs for both current and alarm relay, maki

Call
900S50-0460

900S50-0460

Honeywell / ControlEdge HC900

This I/O scanner module features one port and functions with network communication over Ethernet using the IEEE 802.4/100Base-Tx physical layer. With a weight of 0.79 lbs, it is compact and efficient. The module operates within a temperature range of 0 °C to 60 °C and humidity levels from 10% to 90%

Call
DC2800-CE-1F0-200-000-00-0

DC2800-CE-1F0-200-000-00-0

Honeywell / UDC2800

This model is capable of accepting a diverse range of inputs, including thermocouples (TC), resistance temperature detectors (RTD), millivolt signals, as well as voltage and current inputs. It provides a current output option of either 4 to 20 mA or 0 to 20 mA, along with a Form C E-M relay output r

Call
DC2800-EE-0S0-220-000-00-0

DC2800-EE-0S0-220-000-00-0

Honeywell / UDC2800

The UDC2800 model is equipped with two sets of inputs that support various types: TC, RTD, mV, as well as signals at 0-5V, 1-5V, 0-10V, 0-20mA, and 4-20mA. It also has control output options that include an electro-mechanical relay alongside a 5 Amp relay and alarm feature. With a robust design, the

Call
DC2800-E0-3L0-100-000-00-0

DC2800-E0-3L0-100-000-00-0

Honeywell / UDC2800

This digital controller from the UDC2800 series can handle input signals from thermocouples (TC), RTDs, and mV sources, as well as voltage inputs of 0-5V, 1-5V, and 0-10V. It is rated for a minimum operating temperature of 55°C and a relative humidity level of 90% without condensation. The device is

Call
DC2800-CB-1S0-100-000-00-0

DC2800-CB-1S0-100-000-00-0

Honeywell / UDC2800

This universal digital controller supports a maximum temperature of 55 °C and a minimum of 0 °C. It can function in environments with relative humidity levels ranging from 5% to 90% (non-condensing) and is rated for installation at altitudes up to 2000 meters. The rated vibration frequency is set at

Call