UDA2182-PH1-PH2-NN-N-0E00-EE

UDA2182-PH1-PH2-NN-N-0E00-EE

Honeywell / UDA2182

This universal analyzer allows for dual-channel monitoring of pH and ORP. It features a graphical LCD display with backlighting for visibility and is equipped with a 10-button membrane keypad for user interaction. Operating temperatures range from 0 to 60 °C, and it can be stored between -30 and 70

Call
STD820-A1HC4AS-1-A-AH0-11S-A-10A0-00-0000

STD820-A1HC4AS-1-A-AH0-11S-A-10A0-00-0000

Honeywell / SmartLine

This differential pressure transmitter weighs 8.3 lbs and is constructed with a durability-focused design featuring a diaphragm made of 316L stainless steel. The process head is made from plated carbon steel, while the fill fluid is silicone oil. The gasket is derived from Teflon or PTFE material, d

Call
STD720-E1AC4AS-1-A-AH0-11S-A-10A0-0-0000

STD720-E1AC4AS-1-A-AH0-11S-A-10A0-0-0000

Honeywell / SmartLine

This device operates within a URL range of 400/1000 mbar and a lower range limit of -400/-1000 mbar. It includes a dual-ended head design and has standard venting. The transmitter's materials include a 316 stainless steel head and diaphragm, which ensures durability. It operates efficiently in tempe

Call
STD720-E1HS4AS-1-A-AHA-11S-A-30A0-00-0000

STD720-E1HS4AS-1-A-AHA-11S-A-30A0-00-0000

Honeywell / SmartLine

This differential pressure transmitter includes a maximum turndown ratio of 100:1. The URL is set at 400/1000 mbar, while the LRL measures from -400 to -1000 mbar. It implements a 4-20mA DC analog output and utilizes silicone oil 200 as the fill fluid, ensuring reliable operation.

Call
DR45A1-1000-00-000-0-000000-0

DR45A1-1000-00-000-0-000000-0

Honeywell / DR4500

Designed specifically for the DR4500 series, this circular chart recorder is equipped with one standard pen and comes with a gray door and glass window. It operates in a temperature range from 0 °C to 55 °C and supports minimal relative humidity levels of 5% (non-condensing).

Call
2000-400-150-126-000-00-000000-0-0-00

2000-400-150-126-000-00-000000-0-0-00

Honeywell / HercuLine 2000

This smart actuator features basic motor selection without electronics, providing reliable performance for various tasks. It allows for a rotation of 150 degrees and operates at an input frequency of 60 Hz. The actuator supports 3-wire drive control for up/down adjustments and is designed for high h

Call
2000-200-150-126-000-00-000000-0-0-00

2000-200-150-126-000-00-000000-0-0-00

Honeywell / HercuLine 2000

This actuator operates at an input frequency of 60 Hz and offers a rotation capability of 150 degrees. The device utilizes analog input signals with a 3-wire drive for up and down movement. It can withstand relative humidity from 0% to 99% (non-condensing) and is suitable for storage temperatures ra

Call
900S50-0460

900S50-0460

Honeywell / ControlEdge HC900

This I/O scanner module features one port and functions with network communication over Ethernet using the IEEE 802.4/100Base-Tx physical layer. With a weight of 0.79 lbs, it is compact and efficient. The module operates within a temperature range of 0 °C to 60 °C and humidity levels from 10% to 90%

Call
DC2800-CE-1F0-200-000-00-0

DC2800-CE-1F0-200-000-00-0

Honeywell / UDC2800

This model is capable of accepting a diverse range of inputs, including thermocouples (TC), resistance temperature detectors (RTD), millivolt signals, as well as voltage and current inputs. It provides a current output option of either 4 to 20 mA or 0 to 20 mA, along with a Form C E-M relay output r

Call
DC1701-7-1-1-0-1-0-0-0

DC1701-7-1-1-0-1-0-0-0

Honeywell / UDC1700

Designed for precision, this digital controller operates effectively within a temperature range of 0 °C to 55 °C and functions under varying humidity conditions, with a minimum of 20% and a maximum of 90% (non-condensing). The power supply accommodates a range from 90 to 264 VAC, and it supports ins

Call