753 results
Honeywell / HercuLine 2001
The actuator provides a rotation capacity of 90 degrees and generates a rated torque of 45 Nm. It requires a power supply of 100 to 130 VAC and operates on a single-phase system. The device features an analog output signal range of 0/4-20 mA DC alongside an analog input signal capability of 0/4-20 m
Honeywell / SmartLine
This differential pressure transmitter features a minimum span of 4.0 H2O (10 mbar) and can handle an upper limit of 400 (1000 mbar) as well as a lower limit of -400 (-1000 mbar). It incorporates two remote seals and a maximum turndown ratio of 100:1 for versatile performance. The unit outputs analo
Honeywell / DR4500
This circular chart recorder operates with one input channel, accepting T/C, RTD, Radiamatic signals, as well as mV, 0–5V, and 4–20mA inputs. It includes one control output but lacks auxiliary and external interfaces. The unit features a 12-inch chart for recording and is suitable for a temperature
Honeywell / HercuLine 2002
This smart actuator operates within a power supply range of 100-130 VAC with a single-phase setup and an input frequency of 60 Hz. It supports multiple analog input signals, including 0/4-20 mA and 0-10 Vdc. Local user interaction is made easy through an integrally mounted display and keypad. Notabl
Honeywell / DR4500
This circular chart recorder supports two input channels, each accepting T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA signals. It is certified with UL and CSA listings, ensuring reliable safety standards compliance. The unit uses a standard pen for recording and features a standard door latch, while i
Honeywell / DR4500
This circular chart recorder is designed for a range of input signals including T/C, RTD, and mV, alongside 0–5V and 4–20mA inputs. The recorder operates efficiently within an environment temperature range of 0 °C to 55 °C and does not provide external output capability. It is UL listed and CSA cert
Honeywell / DR4500
Designed for a variety of applications, this control output PCB manages between 1 to 4 analog inputs and supports up to 2 independent PID loop controllers. It features a dual EPROM socket configuration for enhanced memory capabilities and a reliable 3V coin-cell lithium battery for memory backup. Th
Honeywell / HercuLine 2001
Designed to operate with a rated torque of 22.5 Nm and capable of rotating 90 degrees, this actuator utilizes a power supply range of 100 to 130 VAC. Its input frequency is set to 60 Hz and supports single-phase operations. The actuator features multiple analog input signals, including options for 0
Honeywell / HercuLine 2002
This smart actuator operates on a single-phase power supply rated between 100 and 130 VAC. With a maximum torque of 11.5 Nm, it facilitates a shaft rotation of up to 90 degrees. It provides versatile analog input options, including 0/4-20 mA and 0-10 VDC signals. The device is equipped with a local
Honeywell / ControlEdge HC900
This control station has an operating voltage range from 10 to 30 volts and consumes up to 21 watts at 10 volts and 22 watts at 30 volts. It includes a lithium coin cell battery, providing additional support. The unit is rated for an operating temperature between -10 °C and 50 °C.