Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392

Search Results

966 results

966 results
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more
Products

900C70-0460

900C70-0460

Honeywell / ControlEdge HC900

This CPU module can manage up to 15,000 function blocks, allowing for extensive process control capabilities. It features connectivity with two Ethernet RJ-45 communication ports and supports a maximum of 2,304 high-level analog inputs along with 480 analog outputs. Additionally, its digital I/O cap

Call
DR45AT-1000-40-000-0-000000-0

DR45AT-1000-40-000-0-000000-0

Honeywell / DR4500

This circular chart recorder features multiple inputs including T/C, RTD, Radiamatic, and signals of mV, 0–5V, and 4–20mA. It includes one control output with setpoint programming and is outfitted with a standard pen. The device has a gray door with a glass window and utilizes a standard latch mecha

Call
STD720-E1HS4AS-1-A-AHA-11S-A-30A0-00-0000

STD720-E1HS4AS-1-A-AHA-11S-A-30A0-00-0000

Honeywell / SmartLine

This differential pressure transmitter includes a maximum turndown ratio of 100:1. The URL is set at 400/1000 mbar, while the LRL measures from -400 to -1000 mbar. It implements a 4-20mA DC analog output and utilizes silicone oil 200 as the fill fluid, ensuring reliable operation.

Call
2000-400-150-126-015-20-000000-0-0-0

2000-400-150-126-015-20-000000-0-0-0

Honeywell / HercuLine 2000

The actuator provides a rotation range of 150 degrees and is powered by a supply voltage of 100-130 VAC. It supports single-phase input at 60 Hz and features a basic motor with no integrated electronics. This model includes 2 auxiliary switches and analog output signals of dual 1000 Ohm over its ope

Call
2000-050-090-126-000-20-000000-0-0-0

2000-050-090-126-000-20-000000-0-0-0

Honeywell / HercuLine 2000

This actuator features a basic motor without electronic components, ensuring straightforward operation. It offers a torque output of 6.0 Nm and operates at an input frequency of 60 Hz. The device includes two auxiliary switches and utilizes a 3-wire drive for up and down movements. The Honeywell uni

Call
DR45A1-1000-00-000-0-000000-0

DR45A1-1000-00-000-0-000000-0

Honeywell / DR4500

Designed specifically for the DR4500 series, this circular chart recorder is equipped with one standard pen and comes with a gray door and glass window. It operates in a temperature range from 0 °C to 55 °C and supports minimal relative humidity levels of 5% (non-condensing).

Call
2000-400-150-126-000-00-000000-0-0-00

2000-400-150-126-000-00-000000-0-0-00

Honeywell / HercuLine 2000

This smart actuator features basic motor selection without electronics, providing reliable performance for various tasks. It allows for a rotation of 150 degrees and operates at an input frequency of 60 Hz. The actuator supports 3-wire drive control for up/down adjustments and is designed for high h

Call
51309355-505

51309355-505

Honeywell / DR4500

This main processor board operates efficiently between 0 and 40 degrees Celsius. For storage, it can withstand temperatures ranging from 0 to 50 degrees Celsius. This unit is rated for a maximum operating and storage relative humidity of 80% without condensation. It can be utilized effectively at al

Call
DC3500-0E-1000-200-00000-00-0

DC3500-0E-1000-200-00000-00-0

Honeywell / UDC3500

This digital controller supports several input types, including TC, RTD, mV, 0-5V, 1-5V, 0-20mA, and 4-20mA. Although it features a single control loop, it includes a communication interface with additional digital inputs and is equipped with three form C relays rated for 5 Amps each. The operating

Call
50001182-501

50001182-501

Honeywell / GR Series

The 50001182-501 power supply board integrates seamlessly with Multitrend GR Recorders, providing regulated internal DC voltages. It supports input voltages from 100 to 240 VAC and operates effectively at line frequencies of 47 to 63 Hz. Designed for operational stability, it functions within a temp

Call
Showing 91-100 of 966 results