Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392

Search Results

966 results

966 results
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more
Products

STD720-E1HS4AS-1-A-AHA-11S-A-30A0-00-0000

STD720-E1HS4AS-1-A-AHA-11S-A-30A0-00-0000

Honeywell / SmartLine

This differential pressure transmitter includes a maximum turndown ratio of 100:1. The URL is set at 400/1000 mbar, while the LRL measures from -400 to -1000 mbar. It implements a 4-20mA DC analog output and utilizes silicone oil 200 as the fill fluid, ensuring reliable operation.

Call
2000-400-150-126-015-20-000000-0-0-0

2000-400-150-126-015-20-000000-0-0-0

Honeywell / HercuLine 2000

The actuator provides a rotation range of 150 degrees and is powered by a supply voltage of 100-130 VAC. It supports single-phase input at 60 Hz and features a basic motor with no integrated electronics. This model includes 2 auxiliary switches and analog output signals of dual 1000 Ohm over its ope

Call
2000-050-090-126-000-20-000000-0-0-0

2000-050-090-126-000-20-000000-0-0-0

Honeywell / HercuLine 2000

This actuator features a basic motor without electronic components, ensuring straightforward operation. It offers a torque output of 6.0 Nm and operates at an input frequency of 60 Hz. The device includes two auxiliary switches and utilizes a 3-wire drive for up and down movements. The Honeywell uni

Call
DR45A1-1000-00-000-0-000000-0

DR45A1-1000-00-000-0-000000-0

Honeywell / DR4500

Designed specifically for the DR4500 series, this circular chart recorder is equipped with one standard pen and comes with a gray door and glass window. It operates in a temperature range from 0 °C to 55 °C and supports minimal relative humidity levels of 5% (non-condensing).

Call
2000-400-150-126-000-00-000000-0-0-00

2000-400-150-126-000-00-000000-0-0-00

Honeywell / HercuLine 2000

This smart actuator features basic motor selection without electronics, providing reliable performance for various tasks. It allows for a rotation of 150 degrees and operates at an input frequency of 60 Hz. The actuator supports 3-wire drive control for up/down adjustments and is designed for high h

Call
51309355-505

51309355-505

Honeywell / DR4500

This main processor board operates efficiently between 0 and 40 degrees Celsius. For storage, it can withstand temperatures ranging from 0 to 50 degrees Celsius. This unit is rated for a maximum operating and storage relative humidity of 80% without condensation. It can be utilized effectively at al

Call
DC3500-0E-1000-200-00000-00-0

DC3500-0E-1000-200-00000-00-0

Honeywell / UDC3500

This digital controller supports several input types, including TC, RTD, mV, 0-5V, 1-5V, 0-20mA, and 4-20mA. Although it features a single control loop, it includes a communication interface with additional digital inputs and is equipped with three form C relays rated for 5 Amps each. The operating

Call
DC2800-CE-3F0-220-100-00-0

DC2800-CE-3F0-220-100-00-0

Honeywell / UDC2800

This digital controller features capabilities for measuring TC, RTD, and mV inputs, along with voltage and current options including 0-5V, 1-5V, 0-10V, 4-20mA, and 0-20mA. It operates efficiently within an ambient temperature range of 0 °C to 55 °C and is certified by CE, UL, and CSA standards.

Call
50001182-501

50001182-501

Honeywell / GR Series

The 50001182-501 power supply board integrates seamlessly with Multitrend GR Recorders, providing regulated internal DC voltages. It supports input voltages from 100 to 240 VAC and operates effectively at line frequencies of 47 to 63 Hz. Designed for operational stability, it functions within a temp

Call
50008930-001

50008930-001

Honeywell / ControlEdge HC900

This model supports an operating voltage range of 12 to 48 VDC and offers dual redundant power inputs for enhanced reliability. The switch can operate in ambient temperatures from 0 °C to 60 °C and maintains functionality in humidity levels between 5% and 95% (non-condensing). It also includes a sin

Call
Showing 101-110 of 966 results