670 results
Honeywell / HercuLine 2001
This actuator operates on a single-phase system and weighs 27 lbs. It requires a power supply of 100 to 130 VAC and operates at an input frequency of 60 Hz. Input signals can be analog, supporting ranges of 0/4-20 mA, 0/1-5 Vdc, or 0-10 Vdc, and it includes two auxiliary switches for additional cont
Honeywell / UDC3500
This controller has multiple capabilities including three Form C electro-mechanical relay outputs rated at 5 Amps each, alongside additional relay support. The device can manage two control loops and features a real-time clock providing time-stamped data. It can process an array of input types inclu
Honeywell / SmartLine
This gauge pressure transmitter offers a maximum turndown ratio of 100:1, with an upper range limit of 3000 inches of H2O (210 mbar) and a lower range limit of -14.7 inches of H2O (-1 mbar). It comes equipped with a single-ended head and an analog output of 4-20 mA dc, ensuring compatibility with a
Honeywell / DR4500
Designed for versatility, this recorder supports inputs such as T/C, RTD, Radiamatic, and voltage signals ranging from 0–5V and 4–20mA. The DR45AT-1000 features a standard pen for chart recording and operates effectively within an ambient temperature span of 0 °C to 55 °C. Additionally, it includes
Honeywell / UDA2182
This analyzer has inputs for conductivity on both channels. It does not include additional analog outputs or relays and lacks communication options. It functions within a temperature range of 0 °C to 60 °C and has a storage temperature capability of -30 °C to 70 °C. The unit is housed in GE Valox 35
Honeywell / ControlEdge HC900
This CPU module can manage up to 15,000 function blocks, allowing for extensive process control capabilities. It features connectivity with two Ethernet RJ-45 communication ports and supports a maximum of 2,304 high-level analog inputs along with 480 analog outputs. Additionally, its digital I/O cap
Honeywell / DR4500
This circular chart recorder features a 12-inch diameter chart and supports input channels for T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA signals. The operational temperature range spans from 0 °C to 55 °C, allowing it to function effectively in various environments. It is also designed for multiple
Honeywell / HercuLine 2001
This model from the HercuLine 2001 series weighs 27 lbs and is capable of 90 degrees of rotation. It is designed for single-phase operation and can operate on a power supply ranging from 100 to 130 VAC at an input frequency of 60 Hz. The actuator accepts multiple analog input signals, such as 0/4-20
Honeywell / DR4500
This circular chart recorder measures 12 inches in diameter and is capable of functioning within an operating temperature range of 0 °C to 55 °C. It has a weight of 13.2 lbs, facilitating various mounting methods including panel, 2-inch pipe, or surface options. The device operates effectively with
Honeywell / UDA2182
Operating within a temperature span of 0°C to 60°C, the UDA2182 analyzer is suited for various settings. It features a graphical LCD equipped with a white LED backlight for improved visibility. A 10-button membrane keypad facilitates user interaction, while the unit is constructed from durable GE Va