Honeywell / V5055
This valve operates effectively within a temperature range from -40°C to 66°C. It is constructed from die-cast aluminum, ensuring durability. The valve can handle a maximum rated pressure of 15 psi and is rated for CSA valve capacity of 10200 cf/hr. Upstream and downstream tapping configurations are
Honeywell / SLATE
This base module, weighing 2 lbs, operates between specified frequencies of 50 Hz and 60 Hz, making it suitable for a wide range of applications. It is built to function optimally in environments with a temperature range from -29°C to 66°C, and can be stored safely at temperatures as low as -40°C. T
Honeywell / 7800 Series
This flame signal amplifier functions effectively with a signal strength range from 0 to 5.0V DC. It features a dynamic self-checking mechanism and utilizes a PCB edge connector for electrical connections. The unit operates within a temperature range of -40°C to 60°C and is capable of storage in con
Honeywell / SLATE
Part of the SLATE series, the R8001M1150 operates within a temperature range from -28 °C to 70 °C. It supports a communication protocol of RS-485 and features a NEMA 1 enclosure rating for protection. The actuator operates effectively at relative humidity levels of 0 to 99% and is rated for temperat
Honeywell / 301EM Series
The S301-IRF-R134A operates with a measurement range of 0-1000 ppm and provides a resolution of 1 ppm. This sensor features a warm-up time of 15 minutes and has a response time (T90) of 60 seconds. It operates in temperatures from 0°C to 40°C, with humidity levels from 0 to 95% RH, non-condensing.
Honeywell / Sensepoint XCD
This replacement cartridge provides methane detection with a range from 0 to 100% LEL. It features a robust 316 stainless steel housing for durability and is rated IP66 for protection against dust and water. The device operates between 12 to 32 VDC and maintains function across a significant pressur
Honeywell / XNX Universal Transmitters
This transmitter pod is equipped with standard options and communicates using the HART protocol. It offers an analog output signal in the range of 4–20 mA. Designed for a broad environment, it functions at temperatures between -40°C and 65°C and supports humidity levels from 0% to 99% (non-condensin
Honeywell / Other
This electrode supports a range of measuring applications and is classified as a spare part or accessory. It operates effectively in temperatures from -5 degrees Celsius up to 110 degrees Celsius and can tolerate relative humidity levels of up to 80% without condensation. Additionally, it is rated f
Honeywell / Other
The pressure transducer offers exceptional linearity of ±0.10% full scale and an impressive hysteresis of ±0.05% full scale. It remains hermetically sealed and possesses an IP68/NEMA 6P rating, making it resistant to harsh environmental conditions. With a compensated operating temperature range from
Honeywell / HercuLine 2002
This actuator operates with an enhanced-performance motor and employs non-contact position sensors. The actuator allows for 90 degrees of rotation and has a rated torque of 22.5 Nm. It accepts multiple analog input signals, including 0/4-20 mA, 0/1-5V DC, and 0-10V DC, while its output signal utiliz