966 results
Honeywell / GR Series
This display assembly supports a color depth that exceeds 256,000 colors, utilizing an active TFT technology for clear visibility. With an enclosure rated NEMA 4X and an IP66 rating, it protects against harsh environmental conditions. This device operates within a temperature range of 0 °C to 50 °C,
Honeywell / HercuLine 2002
This actuator operates on a single-phase power supply ranging from 100 to 130 VAC, ensuring compatibility with standard power systems. It has a rotation speed of 15 seconds at 60 Hz and can rotate up to 90 degrees. The product features non-contact position sensing and is capable of receiving analog
Honeywell / HercuLine 2001
With a lightweight design at 27 lbs, this actuator employs a single-phase power supply ranging from 100 to 130 VAC. It supports diverse analog input signals including 0/4-20 mA, 0/1-5V DC, and 0-10V DC. The actuator is housed in a robust die-cast aluminum enclosure, ensuring durability in various en
Honeywell / HercuLine 2002
This smart actuator operates on a single-phase power supply rated between 100 and 130 VAC. With a maximum torque of 11.5 Nm, it facilitates a shaft rotation of up to 90 degrees. It provides versatile analog input options, including 0/4-20 mA and 0-10 VDC signals. The device is equipped with a local
Honeywell / ControlEdge HC900
This control station has an operating voltage range from 10 to 30 volts and consumes up to 21 watts at 10 volts and 22 watts at 30 volts. It includes a lithium coin cell battery, providing additional support. The unit is rated for an operating temperature between -10 °C and 50 °C.
Honeywell / HercuLine 2001
This single-phase actuator operates with a power supply range of 100 to 130 VAC and an input frequency of 60 Hz. It accepts various analog input signals, including 0/4-20 mA or 0/1-5 Vdc. The unit includes two auxiliary switches and communicates via an RS-485 Modbus interface.
Honeywell / DR4500
This circular chart recorder includes a 12-inch diameter chart and accommodates multiple input types: T/C, RTD, Radiamatic, as well as mV, 0–5V, and 4–20mA. It supports mounting via panel, 2-inch pipe, or surface methods and functions in relative humidity conditions of 5% to 90% (non-condensing). It
Honeywell / HercuLine 2001
This actuator can rotate up to 150 degrees and incorporates two auxiliary switches. It supports single-phase power with an input frequency of 60 Hz and requires analog input signals of 0/4-20 mA, 0/1-5 Vdc, or 0-10 Vdc. The device utilizes an integrally-mounted keypad and display for ease of operati
Honeywell / GR Series
Featuring a weight of 5.3 lbs, this device supports an input frequency of 60 Hz and operates within a power range of 90-240 VAC using a US power cord. The recorder includes 3 analog inputs but does not provide discrete input or output options. Its internal memory capacity is 1 GB, and it is mounted
Honeywell / HercuLine 2001
This actuator operates on a single-phase system and weighs 27 lbs. It requires a power supply of 100 to 130 VAC and operates at an input frequency of 60 Hz. Input signals can be analog, supporting ranges of 0/4-20 mA, 0/1-5 Vdc, or 0-10 Vdc, and it includes two auxiliary switches for additional cont