DC2800-EE-1L0-100-200-00-0

DC2800-EE-1L0-100-200-00-0

Honeywell / UDC2800

This model integrates multiple input types including TC, RTD, mV, and voltage signals ranging from 0-5V to 0-10 V. It is designed to maintain functionality at a minimum relative humidity of 90% and can be installed at altitudes up to 2000m. The unit incorporates two control outputs, including electr

Call
DC2800-E0-1L0-200-200-00-0

DC2800-E0-1L0-200-200-00-0

Honeywell / UDC2800

This device operates under conditions with a minimum temperature rating of 55°C and requires a relative humidity level of at least 90% (non-condensing). It is equipped with an electro-mechanical relay for control output and is designed for installation at altitudes up to 2000 meters.

Call
DC2800-CB-0F0-200-000-00-0

DC2800-CB-0F0-200-000-00-0

Honeywell / UDC2800

This controller offers a current output that can be set to either 4 to 20 mA or 0 to 20 mA, alongside a single alarm relay. It accepts a variety of input signals, including TC, RTD, mV, and voltage options such as 0-5V and 1-5V. Designed to operate in temperatures from 0°C to 55°C, it functions with

Call
DC2800-EE-0L0-100-200-00-0

DC2800-EE-0L0-100-200-00-0

Honeywell / UDC2800

This model incorporates an array of input capabilities, accepting thermocouples (TC), resistance temperature devices (RTD), and millivolt signals along with voltage inputs of 0-5V, 1-5V, and 0-10V. With an operational temperature range from 0°C to 55°C, this unit is designed to function reliably in

In Stock Ships Tomorrow
DC2800-EE-3L0-200-000-00-0

DC2800-EE-3L0-200-000-00-0

Honeywell / UDC2800

This digital controller supports power ranging from 100 to 240 VAC. It accommodates input types including thermocouples, RTDs, mV signals, and various voltage and current inputs. The controller operates effectively within a temperature range of 0 °C to 55 °C. Its communication capabilities include a

In Stock Ships Tomorrow
DC2800-EE-1F0-200-100-0C-0

DC2800-EE-1F0-200-100-0C-0

Honeywell / UDC2800

This digital controller includes two Form C electro-mechanical relay outputs rated at 5 Amps. The device features a communication interface with one auxiliary output and the option for up to two digital inputs. Relative humidity can range from 5% to 90% (non-condensing), and it operates effectively

Call
DC2800-EE-3F0-200-100-00-0

DC2800-EE-3F0-200-100-00-0

Honeywell / UDC2800

The Honeywell UDC2800 features a configuration for wide-ranging measurement types including TC, RTD, and several voltage and current inputs. With a weight of 3 lbs, it ensures reliable performance in both low and high ambient temperatures. It supports a communication interface, allowing seamless con

Call
DC2800-EE-1L0-200-100-0C-0

DC2800-EE-1L0-200-100-0C-0

Honeywell / UDC2800

This digital controller features an ambient operating temperature range of 0 °C to 55 °C and allows for installation at elevations up to 2000 meters. The first input channel accepts TC, RTD, mV, and various voltage and current signals from 0-5V to 4-20mA. Its communication interface supports one aux

Call
DC2800-EE-2S0-200-100-00-0

DC2800-EE-2S0-200-100-00-0

Honeywell / UDC2800

This digital controller accepts multiple input types including TC, RTD, mV, and different voltage and current signals. It features a Form C electro-mechanical relay for outputs and is certified for compliance with CE, UL, and CSA standards. Its operating temperature range spans from 0 °C to 55 °C, a

Call
DC2800-EB-3L0-100-100-00-0

DC2800-EB-3L0-100-100-00-0

Honeywell / UDC2800

This digital controller accepts a variety of inputs, including TC, RTD, mV, and voltage signals ranging from 0-5V to 0-10V. It is designed for operation in conditions with a minimum rated temperature of 55 °C and relative humidity of 90% (non-condensing). Evaluated for an altitude of up to 2000 m, i

Call
Showing 121-130 of 140 results