Honeywell / 7800 Series
This diagnostic tester supports an input voltage frequency of 50/60 Hz. It works within a temperature range from -18°C to 49°C during operation, while it can withstand storage conditions between -34.5°C and 65°C. The unit dissipates 20 watts of power and includes a 1.0A (3AG) fuse for protection. It
Honeywell / V5055
This valve operates effectively within a temperature range from -40°C to 66°C. It is constructed from die-cast aluminum, ensuring durability. The valve can handle a maximum rated pressure of 15 psi and is rated for CSA valve capacity of 10200 cf/hr. Upstream and downstream tapping configurations are
Honeywell / 7800 Series
Designed for robust performance, this burner control module has a temperature range that spans from a minimum of -40°C to a maximum of 60°C during operation, while storage temperatures can range from -40°C to 66°C. With a humidity tolerance of 85% RH (non-condensing), it supports a maximum connected
Honeywell / 7800 Series
This burner control unit features an operating temperature range from -40°C to 60°C and can be stored between -40°C and 66°C. Its maximum connected load capacity is 2000 VA, while it dissipates a maximum of 10 Watts. Fusing capabilities allow for a maximum of 15A with Type SC fast blow or equivalent
Honeywell / 7800 Series
Rated for temperatures between -40°C and +60°C, the RM7896D1027 is designed for diverse environments. It supports an interrupted pilot type and includes a postpurge timer set to 60 seconds. The control unit has a maximum power dissipation of 10 W and accommodates a total connected load of 2000 VA.
Honeywell / V5055
This product is classified as a high-pressure on-off safety shutoff valve and is constructed from die-cast aluminum. It offers a maximum body rating of 75 psi and can accommodate an operating pressure differential of up to 15 psi. With a valve capacity of 5230 cf/hr, it connects with a 3-inch NPT pi
Honeywell / 7800 Series
With a flame signal output range from 0 to 5.0 volts DC, this flame amplifier boasts a response time of either 0.8 seconds or 3.0 seconds for flame failure detection. It is primarily used in commercial and industrial environments for boiler, burner, and furnace safety monitoring.
Honeywell / V8944
The V8944N1046 is a 2-stage pressure-regulating diaphragm gas valve that rapidly opens and closes within a mere 2 seconds. It connects to a 2-inch pipe and operates at 24 VAC electrical voltage, supporting frequency ranges from 50 Hz to 60 Hz. Built with a die-cast aluminum body, this valve ensures
Honeywell / V8944
This pressure-regulating gas valve works with natural gas and operates at a rated voltage of 24 VAC. It features a slow opening, two-stage design, with a closing time of 2 seconds, making it suitable for various applications. The device integrates a straight-through body pattern and is constructed f
Honeywell / V5055
This gas valve body operates effectively at pressures up to 15 psi and supports a minimum temperature of -40°C, extending to a maximum of 66°C. Equipped with a 1/4-inch spade terminal for electrical connections, it is rated for 120V AC and 60 Hz frequency, suitable for various heating systems.