TVEZGR-61-600-22-0-020-000000-000

TVEZGR-61-600-22-0-020-000000-000

Honeywell / GR Series

This graphic recorder supports a total of 6 analog inputs along with the capability to add 6 more through expansion board options. With an IP55 rating, this device is equipped for standard panel mounting. It requires a power supply between 90-240V AC, with a frequency of 60 Hz and has 1 GB of intern

Call
2002-400-150-126-385-20-100000-1-0-0

2002-400-150-126-385-20-100000-1-0-0

Honeywell / HercuLine 2002

Designed for a variety of applications, this actuator can rotate up to 150 degrees and has a rated torque of 45 Nm. It operates at a speed of 50 seconds for a full rotation at 60 Hz. The power supply requirements range from 100 to 130 VAC for single-phase operation, and it supports multiple analog i

Call
2002-200-090-126-365-20-121000-1-0-0

2002-200-090-126-365-20-121000-1-0-0

Honeywell / HercuLine 2002

This actuator operates with an enhanced-performance motor and employs non-contact position sensors. The actuator allows for 90 degrees of rotation and has a rated torque of 22.5 Nm. It accepts multiple analog input signals, including 0/4-20 mA, 0/1-5V DC, and 0-10V DC, while its output signal utiliz

Call
50084844-504

50084844-504

Honeywell / GR Series

This display assembly supports a color depth that exceeds 256,000 colors, utilizing an active TFT technology for clear visibility. With an enclosure rated NEMA 4X and an IP66 rating, it protects against harsh environmental conditions. This device operates within a temperature range of 0 °C to 50 °C,

Call
2002-200-090-126-300-03-020001-1-1-0

2002-200-090-126-300-03-020001-1-1-0

Honeywell / HercuLine 2002

This actuator operates on a single-phase power supply ranging from 100 to 130 VAC, ensuring compatibility with standard power systems. It has a rotation speed of 15 seconds at 60 Hz and can rotate up to 90 degrees. The product features non-contact position sensing and is capable of receiving analog

Call
DR45AT-1000-00-000-0-300P00-0

DR45AT-1000-00-000-0-300P00-0

Honeywell / DR4500

This circular chart recorder is designed for a range of input signals including T/C, RTD, and mV, alongside 0–5V and 4–20mA inputs. The recorder operates efficiently within an environment temperature range of 0 °C to 55 °C and does not provide external output capability. It is UL listed and CSA cert

Call
2001-200-090-126-200-22-100000-1-0-0

2001-200-090-126-200-22-100000-1-0-0

Honeywell / HercuLine 2001

Designed to operate with a rated torque of 22.5 Nm and capable of rotating 90 degrees, this actuator utilizes a power supply range of 100 to 130 VAC. Its input frequency is set to 60 Hz and supports single-phase operations. The actuator features multiple analog input signals, including options for 0

Call
2002-100-090-126-385-20-100001-1-0-0

2002-100-090-126-385-20-100001-1-0-0

Honeywell / HercuLine 2002

This smart actuator operates on a single-phase power supply rated between 100 and 130 VAC. With a maximum torque of 11.5 Nm, it facilitates a shaft rotation of up to 90 degrees. It provides versatile analog input options, including 0/4-20 mA and 0-10 VDC signals. The device is equipped with a local

Call
2001-200-150-126-280-20-100001-1-0-00

2001-200-150-126-280-20-100001-1-0-00

Honeywell / HercuLine 2001

This actuator features a rated torque of 22.5 Nm and has a total weight of 27 lbs. It accepts various analog input signals, including 0/4-20 mA, 0/1-5 Vdc, and 0-10 Vdc. The built-in communication interface uses RS-485 Modbus. The device can deliver analog output signals of 0/4-20mAdc with options f

Call
DR45AT-1000-00-000-A-000000-0

DR45AT-1000-00-000-A-000000-0

Honeywell / DR4500

This circular chart recorder includes a 12-inch diameter chart and accommodates multiple input types: T/C, RTD, Radiamatic, as well as mV, 0–5V, and 4–20mA. It supports mounting via panel, 2-inch pipe, or surface methods and functions in relative humidity conditions of 5% to 90% (non-condensing). It

Call
Showing 131-140 of 966 results