SPXCDULNRXM

SPXCDULNRXM

Honeywell / Sensepoint XCD

This flame detector weighs 1.05 lb and operates at a nominal voltage of 24 VDC with a current rating of 25 mA. Its IP65 rating provides protection against dust and water. The dual-sensor technology employs Ultraviolet/Infrared (UV/IR) sensing, ensuring a detection range of up to 80 ft (25 m). Its co

Call
SPXCDULNC2R

SPXCDULNC2R

Honeywell / Sensepoint XCD

This remote toxic gas detector can function in extreme temperatures, operating from -40 °C to 65 °C for the transmitter and from -20 °C to 50 °C for the carbon monoxide sensor. It maintains functionality across varying humidity levels, from continuous 20-90% RH to intermittent 0-99% RH. Housed in an

Call
S301-IRF-R123

S301-IRF-R123

Honeywell / 301EM Series

This sensor measures refrigerant gas within a range of 0 to 1000 ppm, offering a resolution of 1 ppm. The response time for achieving 90% of the final value is 60 seconds, and it requires a 15-minute warm-up time. The sensor operates effectively within temperatures ranging from 0°C to 40°C, alongsid

Call
XNX-UTSE-RNNNN

XNX-UTSE-RNNNN

Honeywell / XNX Universal Transmitters

This device operates efficiently within a temperature range of -40°C to 65°C and is built to withstand storage temperatures ranging from -40°C to 75°C. It maintains functionality in humidity conditions of up to 99% (non-condensing) and features a housing made of unpainted 316 stainless steel. Equipp

Call
XNX-UTAE-RNNNN

XNX-UTAE-RNNNN

Honeywell / XNX Universal Transmitters

This gas detector transmitter is equipped with an IP66 rating, ensuring high protection against dust and water ingress. The unit operates efficiently within a temperature range of -40°C to 65°C and supports humidity levels from 0-99% RH (non-condensing). It features a relay output rating of 240 VAC

Call
10269A-1-0-04-2-00010-020-00

10269A-1-0-04-2-00010-020-00

Honeywell / HercuLine 10260

Configured for single-phase applications, this actuator operates at an input frequency of 60 Hz and connects to a 120 VAC power supply. It includes a dual 1000 Ohm film potentiometer and has both clockwise and counterclockwise limit switches. The unit features two auxiliary SPDT switches for added f

Call
DR45AH-1100-10-100-0-SA0PE0-0

DR45AH-1100-10-100-0-SA0PE0-0

Honeywell / DR4500

This circular chart recorder features two input channels, both compatible with T/C, RTD, Radiamatic, and additional voltage and current inputs. It provides one control output and includes an auxiliary output of 4-20 mA. The pen used for recording is of standard type, and it utilizes a 12-inch diamet

Call
TVMIGR-80-2-42-0-020-0U0000-000

TVMIGR-80-2-42-0-020-0U0000-000

Honeywell / GR Series

Designed for a maximum input frequency of 60 Hz, this graphic recorder operates within a voltage range of 90 to 240V AC, utilizing a standard US power cord. Its internal memory capacity is set at 1 GB, supporting ample data storage. The unit can be mounted conveniently using standard panel mounting

Call
10268A-1-1-05-2-00000-000-10

10268A-1-1-05-2-00000-000-10

Honeywell / HercuLine 10260

Operating at an input frequency of 60 Hz, this actuator is a single-phase device constructed from aluminum alloy casting, weighing 40 lbs. The control options include either a 4-20 mADC or a 1-5V DC input, with adjustments manageable through a resistor change. It features both CW (clockwise) and CCW

Call
DR45AP-1100-10-100-0-SA000E-0

DR45AP-1100-10-100-0-SA000E-0

Honeywell / DR4500

Designed within the DR4500 series, this device offers dual input channels accepting various signals, including T/C, RTD, and mV inputs. It features one control output and an auxiliary output of 4-20 mA, ensuring effective measurement and monitoring. The recorder employs a standard pen for accurate r

Call