967 results
Honeywell / GR Series
This graphic recorder is designed with numerous input slots, including four that accommodate 8 analog inputs each and one slot that provides options for relay inputs, digital inputs, or configurable outputs. The operational specifications include a power rating of 90-240V AC and an input frequency o
Honeywell / HercuLine 10260
This actuator operates on a power supply of 120 VAC and utilizes a single-phase configuration, making it adaptable for standard applications. With an operating temperature range from -30 °C to 85 °C, it is suitable for various environments. It includes features such as a dual 1000 Ohm film potentiom
Honeywell / HercuLine 10260
This actuator operates efficiently using a 120 VAC single-phase power supply and is designed for optimal performance at 60 Hz input frequency. It includes a non-contact position sensing mechanism and has an IP66 rating for environmental protection. Key components comprise a dual 1000 Ohm film potent
Honeywell / HercuLine 2001
With a lightweight design at 27 lbs, this actuator employs a single-phase power supply ranging from 100 to 130 VAC. It supports diverse analog input signals including 0/4-20 mA, 0/1-5V DC, and 0-10V DC. The actuator is housed in a robust die-cast aluminum enclosure, ensuring durability in various en
Honeywell / HercuLine 2001
This actuator features a rated torque of 22.5 Nm and has a total weight of 27 lbs. It accepts various analog input signals, including 0/4-20 mA, 0/1-5 Vdc, and 0-10 Vdc. The built-in communication interface uses RS-485 Modbus. The device can deliver analog output signals of 0/4-20mAdc with options f
Honeywell / SmartLine
This gauge pressure transmitter offers an upper range limit of 500 in H2O (35 mbar) and a lower range of -14.7 in H2O (-1 mbar). Constructed from durable materials, such as 316 stainless steel for the process head and 316L stainless steel for the diaphragm, it is designed for reliable performance. I
Honeywell / SmartLine
This device operates within a URL range of 400/1000 mbar and a lower range limit of -400/-1000 mbar. It includes a dual-ended head design and has standard venting. The transmitter's materials include a 316 stainless steel head and diaphragm, which ensures durability. It operates efficiently in tempe
Honeywell / HercuLine 2000
The actuator provides a rotation range of 150 degrees and is powered by a supply voltage of 100-130 VAC. It supports single-phase input at 60 Hz and features a basic motor with no integrated electronics. This model includes 2 auxiliary switches and analog output signals of dual 1000 Ohm over its ope
Honeywell / HercuLine 2000
This actuator operates at an input frequency of 60 Hz and offers a rotation capability of 150 degrees. The device utilizes analog input signals with a 3-wire drive for up and down movement. It can withstand relative humidity from 0% to 99% (non-condensing) and is suitable for storage temperatures ra
Honeywell / Durafet
This Durafet series electrode facilitates insertion and removal for easy maintenance. It operates effectively within a temperature range of 0 to 40 degrees Celsius and tolerates humidity levels up to 80% without condensation. Additionally, it can be stored at temperatures from 0 to 50 degrees Celsiu