969 results
Honeywell / Modutrol IV
This actuator motor operates within a frequency range of 50 to 60 Hz and delivers a torque rating of 150 lb-in. It features a stroke angle adjustable between 90 and 160 degrees, with nominal timing ranging from 30 to 60 seconds. Its fail-safe mode functions without a spring return mechanism, allowin
Honeywell / VP513
This pneumatic valve features an end connection size with an outer diameter of 7/8 inches and accommodates an air connection of 1/8 in. NPT. With a flow capacity of 4 Cv, it additionally supports a close-off pressure rating of 79 psi and a body pressure limit of 250 psi. The spring can be adjusted w
Honeywell / 7800 Series
This model supports a pilot flame establishing period ranging from 4 to 10 seconds and a main flame establishing period of 10 to 15 seconds. It operates effectively at a rated voltage of 120 VAC and accommodates a frequency range of 50 to 60 Hz. Operating conditions are suitable in temperatures from
Honeywell / 7800 Series
Designed to reliably establish flame, this device can handle a maximum connected load of 2000 VA. It features a 10-second flame establishment period and operates efficiently in temperatures ranging from -40°C to 60°C. The unit supports a maximum humidity of 85% RH without condensation, ensuring depe
Honeywell / 7800 Series
This integrated burner control unit establishes a main flame within a maximum of 10 seconds, with a pilot flame taking between 4 and 10 seconds to establish. It mounts directly onto a Q7800A or Q7800B wiring subbase, ensuring easy installation. Operating between temperatures of -40°C and 60°C, it ac
Honeywell / 7800 Series
This relay control module features non-volatile memory, allowing for data retention without power. The device can withstand a minimum operating temperature of -40°C, functioning efficiently up to 60°C. It also has a vibration rating of 0.5 G and supports operation in conditions with relative humidit
Honeywell / 7800 Series
This relay control module weighs 1.81 lbs and functions within a minimum frequency of 50 Hz and a maximum of 60 Hz. It has the option to set the pilot flame establishing period to either 4 seconds or 10 seconds and features a selectable pilot type. The module includes an airflow switch check for sys
Honeywell / Sensepoint XCD
This gas sensor cartridge operates using infrared technology and is specifically calibrated for carbon dioxide detection. With its measuring range set from 0 to 2.00% volume, it can output a signal ranging from 4 to 20 mA. The input voltage requirement is between 16 to 32 VDC, and it features an enc
Honeywell / Other
This module subrack features nine available slots and weighs 5.2 lbs. It conforms to a 19" mounting standard, with construction that includes a backplane PCB and guide rails for easy installation. With a front protection rating of IP20, this subrack is optimal for use in environments with a maximum
Honeywell / HercuLine 10260
This actuator supports a range of control options that include 4-20 mADC or 1-5V DC, given a resistor adjustment. It delivers analog outputs of 4-20 mADC, 0-20 mADC, 0-5V DC, 1-5V DC, or 0-1.25V DC, ensuring versatile integration. The component is protected with an IP66 rating, ensuring reliability