Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392

Search Results

967 results

967 results
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more
Products

51ML10-E1

51ML10-E1

Honeywell / Micro Switch

This limit switch weighs 2.45 lbs and utilizes a side-rotary actuator type with an adjustable hinge rod lever. The SPDT contact configuration is designed for momentary action. Sealed against oils, water, and dust, the switch ensures reliability in challenging conditions.

Call
2108N5100N

2108N5100N

Honeywell / Searchpoint Optima Plus

This module can function with input voltages ranging from 22-27V AC or 29-38V DC and provides relay outputs through 4 DPDT relays rated for 5A at 30 VDC or 250 VAC. It supports analog output on four channels at 4–20 mA, corresponding to individual sensors, and connects via RS-485 Modbus communicatio

Call
2108N4100H

2108N4100H

Honeywell / Searchpoint Optima Plus

The 2108N4100H gas detector features a 3/4-inch NPT threaded spigot for easy installation. It operates effectively within a temperature range of -40 to 65 degrees Celsius for both storage and operational conditions. The device supports HART communication with a 4 to 20 mA output, and it includes adv

Call
S301-IRF-R134A

S301-IRF-R134A

Honeywell / 301EM Series

The S301-IRF-R134A operates with a measurement range of 0-1000 ppm and provides a resolution of 1 ppm. This sensor features a warm-up time of 15 minutes and has a response time (T90) of 60 seconds. It operates in temperatures from 0°C to 40°C, with humidity levels from 0 to 95% RH, non-condensing.

Call
TVMUGR-888800-200-22-2-030-0U000G-014

TVMUGR-888800-200-22-2-030-0U000G-014

Honeywell / GR Series

This graphic recorder is designed with numerous input slots, including four that accommodate 8 analog inputs each and one slot that provides options for relay inputs, digital inputs, or configurable outputs. The operational specifications include a power rating of 90-240V AC and an input frequency o

Call
10264A-1-0-04-2-00013-100-00-00

10264A-1-0-04-2-00013-100-00-00

Honeywell / HercuLine 10260

This actuator operates efficiently using a 120 VAC single-phase power supply and is designed for optimal performance at 60 Hz input frequency. It includes a non-contact position sensing mechanism and has an IP66 rating for environmental protection. Key components comprise a dual 1000 Ohm film potent

Call
2002-200-090-126-365-20-121000-1-0-0

2002-200-090-126-365-20-121000-1-0-0

Honeywell / HercuLine 2002

This actuator operates with an enhanced-performance motor and employs non-contact position sensors. The actuator allows for 90 degrees of rotation and has a rated torque of 22.5 Nm. It accepts multiple analog input signals, including 0/4-20 mA, 0/1-5V DC, and 0-10V DC, while its output signal utiliz

Call
2001-200-150-126-280-20-100001-1-0-00

2001-200-150-126-280-20-100001-1-0-00

Honeywell / HercuLine 2001

This actuator features a rated torque of 22.5 Nm and has a total weight of 27 lbs. It accepts various analog input signals, including 0/4-20 mA, 0/1-5 Vdc, and 0-10 Vdc. The built-in communication interface uses RS-485 Modbus. The device can deliver analog output signals of 0/4-20mAdc with options f

Call
UDA2182-CC1-CC2-NN-N-0000-EE

UDA2182-CC1-CC2-NN-N-0000-EE

Honeywell / UDA2182

Operating within a temperature span of 0°C to 60°C, the UDA2182 analyzer is suited for various settings. It features a graphical LCD equipped with a white LED backlight for improved visibility. A 10-button membrane keypad facilitates user interaction, while the unit is constructed from durable GE Va

Call
STD720-E1AC4AS-1-A-AH0-11C-A-10A0-00-0000

STD720-E1AC4AS-1-A-AH0-11C-A-10A0-00-0000

Honeywell / SmartLine

Designed for a temperature range of -40 to 85 °C, this transmitter provides accurate readings with a maximum turndown ratio of 100:1. Employing both 316 stainless steel for the process head and diaphragm ensures durability. With an operational range extending from -400 to 1000 mbar, this device feat

Call