966 results
Honeywell / GR Series
Featuring a weight of 5.3 lbs, this device supports an input frequency of 60 Hz and operates within a power range of 90-240 VAC using a US power cord. The recorder includes 3 analog inputs but does not provide discrete input or output options. Its internal memory capacity is 1 GB, and it is mounted
Honeywell / SmartLine
This gauge pressure transmitter utilizes piezoresistive sensor technology for precise measurements. It is designed to handle pressure ranges from -14.7 in H2O to 500 in H2O. The device has a robust weight of 8.3 lbs and features a dual-ended head. It is made with durable materials such as plated car
Honeywell / DR4500
This circular chart recorder features input compatibility for thermocouples, RTDs, Radiamatic, and various voltage and current outputs. It has a weight of 13.2 lbs, operates within a temperature range of 0 °C to 55 °C, and is certified with UL listing along with CSA certification.
Honeywell / SmartLine
This gauge pressure transmitter offers a maximum turndown ratio of 100:1, with an upper range limit of 3000 inches of H2O (210 mbar) and a lower range limit of -14.7 inches of H2O (-1 mbar). It comes equipped with a single-ended head and an analog output of 4-20 mA dc, ensuring compatibility with a
Honeywell / DR4500
Designed for versatility, this recorder supports inputs such as T/C, RTD, Radiamatic, and voltage signals ranging from 0–5V and 4–20mA. The DR45AT-1000 features a standard pen for chart recording and operates effectively within an ambient temperature span of 0 °C to 55 °C. Additionally, it includes
Honeywell / ControlEdge HC900
This CPU module can manage up to 15,000 function blocks, allowing for extensive process control capabilities. It features connectivity with two Ethernet RJ-45 communication ports and supports a maximum of 2,304 high-level analog inputs along with 480 analog outputs. Additionally, its digital I/O cap
Honeywell / DR4500
This circular chart recorder features a 12-inch diameter chart and supports input channels for T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA signals. The operational temperature range spans from 0 °C to 55 °C, allowing it to function effectively in various environments. It is also designed for multiple
Honeywell / DR4500
This circular chart recorder measures 12 inches in diameter and is capable of functioning within an operating temperature range of 0 °C to 55 °C. It has a weight of 13.2 lbs, facilitating various mounting methods including panel, 2-inch pipe, or surface options. The device operates effectively with
Honeywell / UDA2182
Operating within a temperature span of 0°C to 60°C, the UDA2182 analyzer is suited for various settings. It features a graphical LCD equipped with a white LED backlight for improved visibility. A 10-button membrane keypad facilitates user interaction, while the unit is constructed from durable GE Va
Honeywell / SmartLine
Designed as a temperature transmitter, the STT850-S-0-A-CDE-11S-A-30A6-00-0000 operates with a single universal input. It has a weight of 2.7 lbs and supports an analog output in the range of 4 to 20 mAdc. This device is housed in a polyester powder-coated aluminum enclosure and can function in temp