Honeywell / Micro Switch
This limit switch operates at a voltage of 125V AC or 115V DC. It features a rated maximum current of 20 A and employs a screw terminal termination style. The device includes one normally open (N.O.) and one normally closed (N.C.) contact, allowing for versatile control options. It requires an opera
Honeywell / Searchpoint Optima Plus
The 2108N4100H gas detector features a 3/4-inch NPT threaded spigot for easy installation. It operates effectively within a temperature range of -40 to 65 degrees Celsius for both storage and operational conditions. The device supports HART communication with a 4 to 20 mA output, and it includes adv
Honeywell / XNX Universal Transmitters
This surface-mounted unit is constructed from painted LM25 aluminum and features an LCD display for easy readability. It includes multiple digital communication options such as HART, MODBUS, and FOUNDATION H1 Fieldbus. The unit has an isolated 4-20 mA analog output for HART communication and a digit
Honeywell / Other
This humidistat employs a direct acting mechanism and has two pipes for fluid conveyance. With an air flow requirement of 0.011 scfm, it operates at a pressure of 25 Psi. It optimally functions within a temperature span of 7 °C to 52 °C and can be stored at temperatures from -34 °C to 66 °C.
Honeywell / Other
This multi-purpose gas sensor utilizes catalytic bead technology, specifically calibrated for methane detection. Its design incorporates a 3/4" NPT male thread for convenient installation. The sensor performs seamlessly at voltages between 16 and 32 VDC while withstanding temperatures from -40°C up
Honeywell / HercuLine 10260
Operating at an input frequency of 60 Hz, this actuator is a single-phase device constructed from aluminum alloy casting, weighing 40 lbs. The control options include either a 4-20 mADC or a 1-5V DC input, with adjustments manageable through a resistor change. It features both CW (clockwise) and CCW
Honeywell / SmartLine
Operating with a maximum turndown ratio of 100:1, this transmitter has an upper range limit of 100 in H2O (7 mbar) and a lower range limit of -100 in H2O (-7 mbar). The diaphragm and process head are both made from durable 316 stainless steel, ensuring longevity and reliability. The fill fluid consi
Honeywell / HercuLine 2000
This actuator operates at an input frequency of 60 Hz and offers a rotation capability of 150 degrees. The device utilizes analog input signals with a 3-wire drive for up and down movement. It can withstand relative humidity from 0% to 99% (non-condensing) and is suitable for storage temperatures ra
Honeywell / ControlEdge HC900
This model supports an operating voltage range of 12 to 48 VDC and offers dual redundant power inputs for enhanced reliability. The switch can operate in ambient temperatures from 0 °C to 60 °C and maintains functionality in humidity levels between 5% and 95% (non-condensing). It also includes a sin
Honeywell / SmartVFD HVAC
Designed with a NEMA 12 rating, this drive is protected against moderate dust and dirt. Its nominal operating voltage is 480V AC, and it is meant for use with 3-phase input. The drive operates efficiently in temperatures as low as 14°F and as high as 104°F.