Honeywell / HercuLine 2002
This actuator operates with an enhanced-performance motor and employs non-contact position sensors. The actuator allows for 90 degrees of rotation and has a rated torque of 22.5 Nm. It accepts multiple analog input signals, including 0/4-20 mA, 0/1-5V DC, and 0-10V DC, while its output signal utiliz
Honeywell / HercuLine 2001
This actuator features a rated torque of 22.5 Nm and has a total weight of 27 lbs. It accepts various analog input signals, including 0/4-20 mA, 0/1-5 Vdc, and 0-10 Vdc. The built-in communication interface uses RS-485 Modbus. The device can deliver analog output signals of 0/4-20mAdc with options f
Honeywell / HercuLine 2000
The actuator provides a rotation range of 150 degrees and is powered by a supply voltage of 100-130 VAC. It supports single-phase input at 60 Hz and features a basic motor with no integrated electronics. This model includes 2 auxiliary switches and analog output signals of dual 1000 Ohm over its ope
Honeywell / SmartLine
Designed for a temperature range of -40 to 85 °C, this transmitter provides accurate readings with a maximum turndown ratio of 100:1. Employing both 316 stainless steel for the process head and diaphragm ensures durability. With an operational range extending from -400 to 1000 mbar, this device feat
Honeywell / Durafet
This replacement electrode operates efficiently with a temperature range from -10 °C to 110 °C. It supports connection options including a 3/4-inch NPT fitting and can be mounted using inline tee configurations. Additionally, the electrode comes with an 8550-ohm thermistor option for enhanced temper
Honeywell / SmartLine
This advanced indicator kit is designed for integrative mounting and allows for field installation flexibility. It operates effectively within a broad temperature range from -40°F to 185°F, and it supports a relative humidity of 0% to 100% in both operating and storage conditions. With substantial s
Honeywell / UDC2800
This model is capable of accepting a diverse range of inputs, including thermocouples (TC), resistance temperature detectors (RTD), millivolt signals, as well as voltage and current inputs. It provides a current output option of either 4 to 20 mA or 0 to 20 mA, along with a Form C E-M relay output r
Honeywell / Durafet
This Durafet series electrode facilitates insertion and removal for easy maintenance. It operates effectively within a temperature range of 0 to 40 degrees Celsius and tolerates humidity levels up to 80% without condensation. Additionally, it can be stored at temperatures from 0 to 50 degrees Celsiu
Honeywell / UDC2800
This digital controller delivers multiple output options, including a 4-20mA or 0-20mA current output, and a 5 Amp Form C electromechanical relay with Alarm 1. It accommodates various input types, such as thermocouple (TC), resistance temperature detector (RTD), and voltage signals ranging from 0-5V
Honeywell / SmartVFD HVAC