Honeywell / VGF Series
This control valve features a 2-way body pattern and has a flow capacity of 70 Cv. Designed for durability, it uses stainless steel for the stem and trim, providing longevity and resistance to wear. The maximum static pressure rating is 175 psi, making it suitable for demanding applications.
Honeywell / SmartVFD HVAC2
This variable frequency drive is rated for a maximum operating temperature of 55 °C and a minimum operating temperature of 0 °C, ensuring reliable performance in various conditions. For storage purposes, it can safely handle temperatures as low as -24 °C and as high as 65 °C. The enclosure rating is
Honeywell / VP513
This unit has an end connection size of 7/8 inches O.D. and connects via a 1/8 inch NPT air connection. It maintains a close-off rating of 79 psi and functions effectively within a body pressure rating of 250 psi. The diaphragm pressure is set at 25 psi, and the valve's spring range is adjustable fr
Honeywell / VBN Series
This control ball valve accommodates a close-off pressure of 100 PSI and boasts a flow capacity rated at 71 Cv. It has a forged brass body and operates with a nominal voltage of 24 VAC. The flow characteristic is equal percentage, providing consistent performance across its operating range.
Honeywell / VBN Series
This commercial ball valve offers a flow capacity of 109 Cv, ideal for efficient fluid control. It features a 3-way body design, female NPT threaded fittings, and utilizes plated brass for its trim material. The flow characteristics exhibit equal distribution from Port A to AB and a linear configura
Honeywell / V5011
This 2-way globe valve has a flow capacity of 46.8 Cv and can withstand a close-off pressure up to 240 psi. It features female NPT connections, along with stainless steel components for durability. The valve operates efficiently in fluid temperatures ranging from 2°C to 120°C.
Honeywell / 7800 Series
This model supports a pilot flame establishing period ranging from 4 to 10 seconds and a main flame establishing period of 10 to 15 seconds. It operates effectively at a rated voltage of 120 VAC and accommodates a frequency range of 50 to 60 Hz. Operating conditions are suitable in temperatures from
Honeywell / 7800 Series
This control module is part of the 7800 Series, featuring frequency capabilities from 50 Hz to 60 Hz. It is capable of managing a pilot flame establishing period of 4 to 10 seconds and a main flame establishing period of 10 seconds. With a postpurge interval of 15 seconds, it improves overall effici
Honeywell / 7800 Series
This diagnostic tester supports an input voltage frequency of 50/60 Hz. It works within a temperature range from -18°C to 49°C during operation, while it can withstand storage conditions between -34.5°C and 65°C. The unit dissipates 20 watts of power and includes a 1.0A (3AG) fuse for protection. It