Honeywell / Sensepoint XCD
This remote toxic gas detector can function in extreme temperatures, operating from -40 °C to 65 °C for the transmitter and from -20 °C to 50 °C for the carbon monoxide sensor. It maintains functionality across varying humidity levels, from continuous 20-90% RH to intermittent 0-99% RH. Housed in an
Honeywell / XNX Universal Transmitters
This surface-mounted unit is constructed from painted LM25 aluminum and features an LCD display for easy readability. It includes multiple digital communication options such as HART, MODBUS, and FOUNDATION H1 Fieldbus. The unit has an isolated 4-20 mA analog output for HART communication and a digit
Honeywell / Other
This humidistat employs a direct acting mechanism and has two pipes for fluid conveyance. With an air flow requirement of 0.011 scfm, it operates at a pressure of 25 Psi. It optimally functions within a temperature span of 7 °C to 52 °C and can be stored at temperatures from -34 °C to 66 °C.
Honeywell / Other
This pilot burner operates efficiently under a gas inlet pressure of 5 to 50 mbar, while air inlet pressure requirements range from 5 to 40 mbar. Featuring an ionization electrode for precise flame control and a direct spark ignition system powered by a 5 kV transformer, it easily ignites under vari
Honeywell / Other
This multi-purpose gas sensor utilizes catalytic bead technology, specifically calibrated for methane detection. Its design incorporates a 3/4" NPT male thread for convenient installation. The sensor performs seamlessly at voltages between 16 and 32 VDC while withstanding temperatures from -40°C up
Honeywell / HercuLine 10260
This actuator supports a range of control options that include 4-20 mADC or 1-5V DC, given a resistor adjustment. It delivers analog outputs of 4-20 mADC, 0-20 mADC, 0-5V DC, 1-5V DC, or 0-1.25V DC, ensuring versatile integration. The component is protected with an IP66 rating, ensuring reliability
Honeywell / SmartLine
Operating with a maximum turndown ratio of 100:1, this transmitter has an upper range limit of 100 in H2O (7 mbar) and a lower range limit of -100 in H2O (-7 mbar). The diaphragm and process head are both made from durable 316 stainless steel, ensuring longevity and reliability. The fill fluid consi
Honeywell / HercuLine 2000
This actuator operates at an input frequency of 60 Hz and offers a rotation capability of 150 degrees. The device utilizes analog input signals with a 3-wire drive for up and down movement. It can withstand relative humidity from 0% to 99% (non-condensing) and is suitable for storage temperatures ra
Honeywell / UDC3500
This digital controller operates with a single control loop and can accept multiple input types, including TC, RTD, and mV signals, as well as 0-5V, 1-5V, 0-20mA, and 4-20mA. It operates optimally within an ambient temperature range of 15 °C to 55 °C and is rated for relative humidity levels between
Honeywell / ControlEdge HC900
This model supports an operating voltage range of 12 to 48 VDC and offers dual redundant power inputs for enhanced reliability. The switch can operate in ambient temperatures from 0 °C to 60 °C and maintains functionality in humidity levels between 5% and 95% (non-condensing). It also includes a sin