969 results
Honeywell / Other
This humidistat employs a direct acting mechanism and has two pipes for fluid conveyance. With an air flow requirement of 0.011 scfm, it operates at a pressure of 25 Psi. It optimally functions within a temperature span of 7 °C to 52 °C and can be stored at temperatures from -34 °C to 66 °C.
Honeywell / Other
This pilot burner operates effectively with LPG, natural gas, and coke oven gas, requiring inlet pressures between 5 and 50 mbar for gas and 5 to 40 mbar for air. The direct spark ignition uses a 5 kV ignition transformer, with an ionization electrode for flame control. It accommodates pipe connecti
Honeywell / Other
This multi-purpose gas sensor utilizes catalytic bead technology, specifically calibrated for methane detection. Its design incorporates a 3/4" NPT male thread for convenient installation. The sensor performs seamlessly at voltages between 16 and 32 VDC while withstanding temperatures from -40°C up
Honeywell / HercuLine 10260
This actuator supports a range of control options that include 4-20 mADC or 1-5V DC, given a resistor adjustment. It delivers analog outputs of 4-20 mADC, 0-20 mADC, 0-5V DC, 1-5V DC, or 0-1.25V DC, ensuring versatile integration. The component is protected with an IP66 rating, ensuring reliability
Honeywell / UDA2182
This universal analyzer allows for dual-channel monitoring of pH and ORP. It features a graphical LCD display with backlighting for visibility and is equipped with a 10-button membrane keypad for user interaction. Operating temperatures range from 0 to 60 °C, and it can be stored between -30 and 70
Honeywell / SmartLine
This differential pressure transmitter weighs 8.3 lbs and is constructed with a durability-focused design featuring a diaphragm made of 316L stainless steel. The process head is made from plated carbon steel, while the fill fluid is silicone oil. The gasket is derived from Teflon or PTFE material, d
Honeywell / ControlEdge HC900
This model supports an operating voltage range of 12 to 48 VDC and offers dual redundant power inputs for enhanced reliability. The switch can operate in ambient temperatures from 0 °C to 60 °C and maintains functionality in humidity levels between 5% and 95% (non-condensing). It also includes a sin
Honeywell / SmartLine
This advanced indicator kit is designed for integrative mounting and allows for field installation flexibility. It operates effectively within a broad temperature range from -40°F to 185°F, and it supports a relative humidity of 0% to 100% in both operating and storage conditions. With substantial s
Honeywell / SmartLine
This temperature probe assembly includes a 3-wire IEC Pt100 sensor in an ungrounded configuration. It operates effectively within temperature ranges of 0 to 40 degrees Celsius and supports storage conditions from 0 to 50 degrees Celsius. The assembly utilizes a threaded bar stock for the thermowell
Honeywell / UDC1200
This controller incorporates a limit control functionality and features a relay output in Option Slot 1. In Slot 2, it provides a 4-20 mA linear DC output, while Slot 3 is not utilized. The controller can handle an operating temperature range from 0°C to 55°C and is capable of being installed at alt